Parts List for Models OFP42N/OFP42LP 

 

Part No.                         Description 

Fireplace Accessories 

Fireplace Part Numbers 

OFP42SS                      Surround Stainless Steel 

                                      Coverage (37”H x 42-3/16” W) 

OFP42N                     Outdoor Fireplace Black 55,000BTU 

OFP42WCSS                     Weather Cover (Stainless Steel) 

OFP42LP                   Outdoor Fireplace Black 55,000BTU 

OFP42WCBL                     Weather Cover (Black) 

OFP42NS                  Outdoor Fireplace Stainless 55,000BTU 

OFP42-P642                  Safety Switch (Weather Cover) 

OFP42LPS                Outdoor Fireplace Stainless 55,000BTU 

OFP42SA                      Spark Assist 

Replacement Burner Assembly 

GFRC                            Remote Control On/Off 

42OFP-BNGSI             Burner Assembly- Natural Gas  

                                     c/w Valve System                                           

ZIRC                              Remote Control Millivolt (On/Off with LED) 

                                      (Model I) 

42OFP-BLPSI              Burner Assembly- Liquid Propane  

                                     c/w Valve System   

DCHS                             Remote Control Heatshield 

Valve System Parts 

Liners 

1001-P640SI                 Valve NGTMV 

OFP42RLT              Refractory Liner Traditional /Reversible              

1001-P639SI                 Valve LPTMV 

OFP42RLH             Refractory Liner Herringbone /Reversible 

1001-P503SI                 Pilot NG 

Miscellaneous and Replacement Parts 

1001-P504SI                 Pilot LP 

42OFP-126                   Stainless Steel Pullscreens – 2 Each 

1001-P136WR              Thermopile 

42OFP-131                   Pullscreen Rods – 2 Each 

1001-P132SI                Pilot Orifice NG  

42OFP-108                   Deflector Hood 

1001-P150SI                Pilot Orifice LP 

42OFP-108SS              Deflector Hood 

1000-220                      Pilot Tube ¼” 

1000-214                     #Piezo Igniter 1244-17 MARK 21 

1001-P069SI                Electrode Sparker 915.069 TC SIT 

1000-215                     #Pal Nut (18MMXI.5MM)BLK(1364.03) 

Fireplace Requirements 

1000-218                     #Switch Ivory (1451/001) 

Log Sets or Rock Kits required for Fireplace 

1000-255                     #Orifice Brass – (State Size) 

LOGF37                        Log Set -7pce. Burnt Oak 

Conversion Kit (SIT Valve Only) 

MQROCK1                   Rock Set Tan 

42OFP-CKNG               NG Conversion Kit 

MQROCK2                   Rock Set Natural 

42OFP-CKLP                 LP Conversion Kit 

MQROCK3                   Rock Set Multi-Color  

MQG10W                     Decorative Glass ½” White 10lbs. 

MQG10B                      Decorative Glass ¼” Black 10lbs. 

 

 

22

Summary of Contents for OFP42LP

Page 1: ...d installer service agency or the gas supplier This manual must be used for installation and retained by the homeowner for operation and maintenance Save this manual for future reference Please contact your dealer for any questions or concerns 2340 Logan Ave Winnipeg MB Canada Phone 204 632 1962 Printed in Canada PART 42OFP MAN September 18 2014 Warning Improper installation adjustment alteration ...

Page 2: ...Walls 7 7 7 Screened Porch Installation 7 Clearance Specifications 8 Gas Line Installation 9 Gas Specifications 9 Brick Panel Installation 10 Curtain and Hood Installation 10 Installing Stainless Steel Surround 11 Log Placement 12 MQ Rock Setup 13 MQ Rock and Glass Setup 14 Lighting Instructions 15 Burner System Maintenance 16 Conversion Kit Instructions Part A 16 Gas Conversion Burner Part A 17 G...

Page 3: ...ppliance be modified Any parts that have to be removed for servicing should be replaced prior to operating this appliance 15 Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance 16 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional servic...

Page 4: ...e testing of the system at test pressures in excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa Installation Regulations This gas appliance must be installed by a qualified installer in accordance with loc...

Page 5: ...OFP42N OFP42LP Pre Installation Questions and Answers 5 ...

Page 6: ...nto position fastened with Screws before installation Dimensions allow for in front of framing tabs for finishing materials Framing Clearances to Fireplace and Standoffs Unless otherwise noted Bottom 0 Sides 0 Adjacent side wall 3 1 2 Floor of fireplace to ceiling 7 Low Profile Enclosure 43 1 2 Minimum Back 0 Top 0 6 ...

Page 7: ...feet Minimum ceiling height 92 inches A minimum of two 2 walls can be screened but must be open to outside ventilation with a minimum screen area of 64 sq feet and a minimum side wall height of 78 inches Notice A qualified service person must install firebox Follow all local codes Warning Improper installation adjustment alteration service or maintenance can cause injury or property damage Read th...

Page 8: ...3ft horizontally from the center line of the regulator Not allowed Vinyl Minimum Floor to Ceiling Height is 85 inches NOTE Diagrams Illustrations not to scale A fireplace shall not open directly above a sidewalk or paved driveway which is located between two single family dwellings and services both swellings Only permitted if veranda porch deck or balcony is fully open on a minimum of 2 sides ben...

Page 9: ...ution 8 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2psig 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or les...

Page 10: ... the Brick Clips and Screws in the Firebox Top Replace Log Support Note Brick Panels can also be installed reversed with the brick pattern against the firebox wall This will give a dark Textured Stone look to the inside of the firebox OFP42N OFP42LP Installing Curtain and Hood Curtain 1 Slide curtain onto rod 2 Slide rod into hole in Side Frame 3 Slide rod into Rod Hanger Bracket 4 Press on Pushnu...

Page 11: ...e as they will be replaced by parts of the Surround 3 Remove Access Panel Brackets by removing DT Screws These Brackets will be reused with the Surround Part 2 Installing the Surround See Surround Drawing above for reference 1 Place Firebox Ledge Cap 3 and Bottom Cover 4 into position on the Fireplace 2 Slide Surround Top 7 onto Surround Sides 5 6 Place Surround Top and Sides onto fireplace 3 Inse...

Page 12: ...of the Pan Burner as shown Leave the Log Placement Pins exposed Step 2 Place Log 1 onto Rear Log Holder and up to Brick Panel Step 3 Place Logs 2 3 on top of Log 1 Locate holes On bottom of logs 4 5 and place these onto Log Place ment Pins as shown in the Photograph above Step 4 Locate holes on Logs 6 7 and place these onto Locating Pins of Logs 2 5 place Large Lava Rock around and in front of Log...

Page 13: ... use any materials other than those supplied or specified for this fireplace NOTE 1 4 Lava Rock maybe substituted with MQG10W B Step 1 Place 1 4 Lava Rock Onto and around Burner Pan as shown Do Not place lava rock into pilot shield assembly area Step 2 Suggested MQROCK Placement Position rocks 1 and 3 as shown Step 3 Position rock 4 as shown Step 4 Position rock 6 as shown Step 5 Position remainin...

Page 14: ... Decorative Glass White or Black Do NOT use any materials other than those supplied or specified for this fireplace Step 1 Remove Rear Log Holder Step 2 Place Glass onto and around Burner Pan as shown do not place glass into the Pilot Shield assembly area NOTE It is not necessary to place rocks over glass Step 3 Position Rocks as per MQROCK Set up or position randomly as shown MQG10 W B and MQROCK...

Page 15: ...then pull forward 2 Refer to Millivolt Lighting Instructions below Recommended Maximum Lead Length Double Wire When Using Wall Switch Wire Size Max Length 14ga 100ft 16ga 64ft 18ga 40ft 20ga 25ft 22ga 16ft Pilot Burner Adjustment Adjust pilot screw to provide proper sized flame Caution Do not wire 120 Volt Power to millivolt switches or thermostat 15 ...

Page 16: ...there are no problems with the burner tube The pilot flame should also be inspected monthly to ensure proper operation Flame should appear similar to above picture Pilot Shield area must be kept clear OFP42NG OFP42LP Conversion Kit Instructions PART A Kit Number Description Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator 42OFP CKLP LP Conversion Millivolt 1001 ...

Page 17: ...rner of the firebox 3 Invert Burner Pan 4 Adjust Air Shutter opening to appropriate size NG Open LP Fully Open 5 Remove existing Orifice and replace with new one NG 20 LP 42 6 Replace Burner Pan OFP42N OFP42LP Gas Conversion Pilot Part B 1 Shut off the gas supply to the appliance 2 Allow the pilot burner to cool to room temperature Warning Touching a hot pilot burner can result in injury 3 Using a...

Page 18: ...OFP42NG OFP42LP Gas Conversion Valve Part C 18 ...

Page 19: ...ating sufficient voltage Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch OFF Replace faulty generator if reading is below specified minimum Plugged burner orifice Check burner orifice for stoppage and remove Defective automatic valve operator Remove all swit...

Page 20: ...OFP42N OFP42LP Electronic Spark Assist Part Number OFP42SA A Battery powered module is available to assist in lighting the pilot burner See below for installation 20 ...

Page 21: ...over 3 Tighten nuts with a 7 16 wrench Installation Instructions 1 Turn Valve Control Knob to the off position and wait until the fireplace is cool 2 Move Curtains toward the center of the fireplace allowing a 7 space between curtains and frame sides See fig 1 below 3 Slide the Weather Cover up behind the top lip of the firebox Then Push the bottom of the Weather Cover into the firebox and allow i...

Page 22: ...lve NGTMV OFP42RLT Refractory Liner Traditional Reversible 1001 P639SI Valve LPTMV OFP42RLH Refractory Liner Herringbone Reversible 1001 P503SI Pilot NG Miscellaneous and Replacement Parts 1001 P504SI Pilot LP 42OFP 126 Stainless Steel Pullscreens 2 Each 1001 P136WR Thermopile 42OFP 131 Pullscreen Rods 2 Each 1001 P132SI Pilot Orifice NG 42OFP 108 Deflector Hood 1001 P150SI Pilot Orifice LP 42OFP ...

Page 23: ...OFP42N OFP42LP Limited Warranty 23 ...