background image

Installation Instructions 

 

HBZDV3624, HBZDV3628 

Models:

 HBZDV3624N, HBZDV3624NE, HBZDV3624NE2, HBZDV3624LP, HBZDV3624LPE, HBZDV3624LPE2 are 

Certified to:

 ANSI Z21.88-2017 • CSA 2.33:2017 Vented Gas Fireplace Heaters, CSA 2.17-2017 

Models:

 HBZDV3628N, HBZDV3628NE, HBZDV3628NE2, HBZDV3628LP, HBZDV3628LPE, HBZDV3628LPE2 are 

Certified to:

 ANSI Z21.88-2017 • CSA 2.33-2017 Vented Gas Fireplace Heaters, CSA 2.17-2017 

 

 

 

 
  
 
 

 

 

For Propane Horizontal installations the 
venting must be a minimum of one foot 
vertical off the flue before going horizontal. 

A Division of R-Co. Inc. 

2340 Logan Avenue 

Winnipeg, Manitoba, Canada R2R 2V3 

Ph: (204) 632-1962 

Printed in Canada August 28, 2019 

Part # 36HB-MAN17 

INSTALLER: Leave this manual with the 
appliance. 
 
CONSUMER: Retain this manual for future 
reference. 

This appliance may be installed in an 

aftermarket, permanently located, 

manufactured home (USA only) or mobile 

home, where not prohibited by local 

codes. 

This appliance is only for use with the 

type of gas indicated on the rating 

plate. This appliance is not convertible 

for use with other gases, unless a 

certified kit is used.

 

VENTED GAS FIREPLACE HEATER: 

NOT FOR USE WITH SOLID FUEL. 

Summary of Contents for HBZDV3624

Page 1: ...e foot vertical off the flue before going horizontal A Division of R Co Inc 2340 Logan Avenue Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada August 28 2019 Part 36HB MAN17 INSTALLE...

Page 2: ...GC44 Placement 24 26 MQLOGC45 Oak Logset Placement 27 28 MQRSP3 with Pilot Shield 29 Installing MQRSP3 30 Pilot Shield RSP1 RSP2 31 MQROCK1 MQRSP3 32 33 Burner System Gas Line Installation 34 Millivol...

Page 3: ...izontal Venting Table From Bottom of Fireplace 58 Venting Straight Up Through Roof 59 60 Fireplace Installations Using Co Linear Flex Kits 61 Glass Safety Termination Cap Safety 62 Approved for Power...

Page 4: ...e sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can...

Page 5: ...until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screens To install screens hook bottom clip onto glass door frame then press down and push upper cli...

Page 6: ...frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance b...

Page 7: ...installation D A metal or plastic identification plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to...

Page 8: ...DV3628LP LPE LPE2 MAY BE INSTALLED IN MANUFACTURED MOBILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada...

Page 9: ...r to the indoor gas fireplace being installed A Minimum sheltering cover overhang of 1 2 the distance from the base of the fireplace to the ceiling base of roofline is required EXAMPLE The bottom of t...

Page 10: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Page 11: ...a 90 degree bend maintain a minimum of two and a half 2 5 inches above the bend in enclosures 5 Hearth is not mandatory but is recommended for aesthetic purposes For HBZDV with louvers combustible fl...

Page 12: ...HBZDV36 WITH HB36CVCK CLEAN VIEW CIRCULATING KIT HBZDV36 Framing and Facing Requirements Non Combustible Header Attached AA Non Combustible Header Attached AA AA AA AA 12...

Page 13: ...fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree bend in Minimum Enclosure of 42 to 43 inches 3 1 2 inches 89 mm All Vent Systems Top of 90 degree bend in Enclosure over 43...

Page 14: ...he top trim and bracket together 2 Place Lower Trim onto fireplace 5 Push bottom side of trop trim toward fireplace The lip on the bottom side of top trim must be inserted into fireplace 3 Attach left...

Page 15: ...s HB36 HB42 HB47 Mantels Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a combustible...

Page 16: ...r over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top bo...

Page 17: ...Fan Installation for HBZDV 36 42 47 17...

Page 18: ...rounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wir...

Page 19: ...3624 AND HBZDV3628 1 Place rear brick panel against rear of fireplace 2 Loosen screws holding brick clips in position Rotate clips up out of the way 3 Place bottom of side brick over front lip of fire...

Page 20: ...firebox by tilting top of Back Panel towards you and sliding bottom of Back Panel over burner system For HB47PL use supplied screw to attach Back Panel to firebox See Ref 2 4 Loosen screws holding Bri...

Page 21: ...tension is lost 1 To remove the top latch remove the 2 hex screws that secure it in place They are located in the firebox 2 Once all the screws are removed the latches will slide out of place 3 There...

Page 22: ...ront burner to the surface of the ember plates and over crossover to the same height as ember plates Height on front burner 1 2 to 3 4 Height on ember plates 3 4 to 1 Do not cover back air openings on...

Page 23: ...ght crossover log across front and back logs using the log placement pin as a guide Step 8 Place left crossover log across front and back logs using the log placement pin as a guide Step 9 Place decor...

Page 24: ...1 Position rear log over rear log holder and lower into position Be sure that the log does not sit on rear burner but behind and lower than burner Step 2 Locate flat surface on Log 2 and place directl...

Page 25: ...terial from plastic bag tear off dime and nickel sized pieces and place directly onto front burner tube and crossover tube NOTE Do not place embers onto rear burner tube Step 5 Position Log 4 into gro...

Page 26: ...e 3rd grate post from the right and position upper section of Log 8 against Logs 2 and 7 Step 10 Place crushed rocks onto firebox bottom NOTE Do not place crushed rock onto burner tubes 6 7 8 LOGC44 P...

Page 27: ...irebox Floor and against left side of Grate Bar Step 3 Rest the Small Branch end of Log 3 onto Rear Log Holder Next place Flattened area of Log 3 onto firebox floor between the right end of Grate Bar...

Page 28: ...ace Log 6 onto Log 1 and Log 5 making sure to position between the end and center flames evenly There should be no impingement of flames or sooting may occur Step 8 Place Log 7 onto empty spot on Rear...

Page 29: ...h Pilot Shield WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal...

Page 30: ...to burner system without pre punched holes 1 Use the rock platform as a template for the holes to be drilled Center platform on burner system 1 from the back of firebox Ref 1 and mark the location of...

Page 31: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 31...

Page 32: ...ock platform mount holes attach the rock platform to the burner pan as shown STEP 4 Fill around the rock platform with lava rock Sprinkle vermiculite over top of the lava rock Do not place lava rock o...

Page 33: ...s STEP 6 Place rocks 3 into position as shown Do not place rocks directly onto the burner tubes STEP 7 Place rocks 4 into position as shown STEP 8 Place rocks 6 into position as shown STEP 9 Place rem...

Page 34: ...Gasline Installation Gasline Specifications HBZDV3624N NE NE2 HBZDV3624LP LPE LPE2 HBZDV3628N NE NE2 HBZDV3628LP LPE LPE2 34...

Page 35: ...ly the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then conti...

Page 36: ...ition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure res...

Page 37: ...ck log holder on applicable units only and remove Remove screws from perimeter of burner system pan lift pan at one back corner and rotate pan up from back of firebox Make sure when tilting up and rem...

Page 38: ...ART A Kit Number Description Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator 3624HB CKLP 3628HB CKLP Propane Conversion Millivolt 1001 P167SI 30 977 167 53 52 1000...

Page 39: ...to the correct opening using a drill bit or tape measure Retighten screw Reinstall burner at this time reversing STEPS 3 2 and 1 11 Follow instructions supplied with the conversion HI LO to convert t...

Page 40: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...

Page 41: ...Gas Conversion for Modulator PART C WARNING WARNING 41...

Page 42: ...ppliance is still operable NOTE In certain instances the IPI Main Module requires resetting This can occur if the system is unable to ignite the pilot or the main burner in the allotted time period Th...

Page 43: ...splay on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set...

Page 44: ...or 1002 P910si Electrode Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62...

Page 45: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 45...

Page 46: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 46...

Page 47: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...

Page 48: ...Configuration 3 Remote ON OFF variable HI LO and fan capabilities Refer to the fan installation removal section for fan installation 48...

Page 49: ...clockwise to off Located behind the access panel 7 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above...

Page 50: ...13 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 14 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 15 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 16 1001 P280SI TC Tubing W Fittings 1 8 2 1...

Page 51: ...d to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 module may now be turned on off manually x4 co...

Page 52: ...ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON OFF Key 2 Press the Mode Key Dis...

Page 53: ...Proflame 2 Remote Control 53...

Page 54: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 54...

Page 55: ...55...

Page 56: ...u h 3 kW and 50 000 Btu h 15 kW 12 in 30 cm for appliances 50 000 Btu h 15 kW K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally L Clearance abo...

Page 57: ...es provided in this manual Apply a bead of Mill Pac high temp sealant to all joints of pipes adapters and termination when using Kingsman Flex Z Flex Venting venting and Simpson Duravent venting NOTE...

Page 58: ...ht of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertic...

Page 59: ...rulers or by using a roof pitch card Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the sh...

Page 60: ...upport configuration B Flex bend configuration C Termination mounting Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requireme...

Page 61: ...ance The Intertek safety certification does not apply to this installation Before installing the appliance using this method contact the Authority Having Jurisdiction to determine if this installation...

Page 62: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Page 63: ...s are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer...

Page 64: ...4 6 5 8 venting to 5 8 For Power Vent installations where flex pipe will be used up to the Power Vent unit Z47PVA Pipe Reducer 8 Sm 7 Sm Pipe Reducer 5 Sm 4 Sm Adapts PVH58 to accept 4 7 Flex Pipe On...

Page 65: ...stem HBZDV3624N 3624HB BLPSI Burner Assembly Liquid Propane c w Valve System HBZDV3624LP 3628HB BNGSI Burner Assembly Natural Gas c w Valve System HBZDV3628N 3628HB BLPSI Burner Assembly Liquid Propan...

Page 66: ...verts from 15 40 to under 15 FDVHT Horizontal Vent Termination FDVHSQ Horizontal Square Termination Z47ST24 Horizontal Snorkel Termination 24 Z47ST36 Horizontal Snorkel Termination 36 FDVHSCU Safety C...

Page 67: ...Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replac...

Page 68: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...