![Kinghome KW09HUCA4D Instruction Manual Download Page 72](http://html1.mh-extra.com/html/kinghome/kw09huca4d/kw09huca4d_instruction-manual_1970323072.webp)
69
Installation and Maintenance
Service Manual
5. Diagnosis for failure start up malfunction (AP1 below is control board of outdoor unit)
Main detection point:
● If the compressor wiring is correct?
● If the stop time of compressor is enough?
● If the compressor is damaged?
● If the refrigerant charging is too much?
Malfunction diagnosis process:
Energize the unit
and start it
If the compressor wire COMP(UVW) is
well connected and connection sequence
is correct
Replace control board AP1
Replace the
compressor
If malfunction is
removed?
If the stop time of compressor
is more than 3min?
No
If the stop time is not enough and the
high and low pressure of system is not
balance , please start it after 3min
Improve the connection situation
of control board AP1 and
compressor COMP, connect it
with wiring diagram
No
Yes
N
If the refrigerant charging is
too much?
Yes
Does the unit start
up normally?
N
Charge the
refrigerant according
to service manual
Yes
Does the unit start
up normally?
No
Yes
End
No
No