Kinghome KW09HQ1B8A Instruction Manual Download Page 33

2

9

Requirements for electric connection

Safety precaution

Grounding requirement

1. Must follow the electric safety regulations when installing the unit.

    air switch.

3. Make sure the power supply matches with the requirement of air conditioner.

    Unstable power supply or incorrect wiring or malfunction. Please install proper 

    power supply cables before using the air conditioner.

4. Properly connect the live wire, neutral wire and grounding wire of power socket.

5. Be sure to cut off the power supply before proceeding any work related to 

    electricity and safety.

7. If the supply cord is damaged, it must be replaced by the manufacturer, its 

8. The temperature of refrigerant circuit will be high, please keep the interconnec-

    tion cable away from the copper tube.

9. The appliance shall be installed in accordance with national wiring regulations.

    grounding with specialized grounding device by a professional. Please make 

    sure it is always grounded effectively, otherwise it may cause electric shock.

2. The yellow-green wire in air conditioner is grounding wire, which can't be used 

    for other purposes.

3. The grounding resistance should comply with national electric safety regulations.

4. The appliance must be positioned so that the plug is accessible.

5. An all-pole disconnection switch having a contact separation of at least 3mm in 

Summary of Contents for KW09HQ1B8A

Page 1: ...AIR CONDITIONER MODEL KW09HQ1B8A KW09HQ1B8D KW12HQ1B8A KW12HQ1B8D KW18HQ1B8D KW24HQ1B8D INSTRUCTION MANUAL...

Page 2: ......

Page 3: ...ng 38 Leakage detection 38 Check after installation 39 Test and operation Test operation 39 Attachment 40 Pipe expanding method Configuration of connection pipe 42 Safety precautions for installing an...

Page 4: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Page 5: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Page 6: ...amage 2 Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do no...

Page 7: ...ables before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket...

Page 8: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions WARNING wire which can t be used for other purposes The grounding resistance...

Page 9: ...her must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be 5...

Page 10: ...ns FCC STATEMENT accordance with the instructions may cause harmful harmful interference in a residential installation This undesired operation frequency energy and if not installed and used in Howeve...

Page 11: ...h Industry Canada licence This equipment complies with FCC s and IC s RF radiation exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must be installed a...

Page 12: ...nce de 20 cm s pare l appareil l exception du combin des utilisateurs avec ceux ci Les installateurs doivent s assurer qu une 8 Working temperature range Indoor side DB WB C F Outdoor side DB WB C F M...

Page 13: ...please refer to actual products Parts Name Indoor Unit Outdoor Unit air inlet panel aux button horizontal louver air outlet air inlet Connection wire air outlet NOTICE Actual product may be different...

Page 14: ...el For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display For some model heating indicator temp indica...

Page 15: ...on TEMP button I FEEL button LIGHT button CLOCK button TIMER ON TIMER OFF button SLEEP button button Send signal Turbo mode 8 heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up...

Page 16: ...ill give out a sound Operation indictor is ON red indicator After that you can operate the air conditioner by using remote controller Under on status pressing the button on the remote controller the s...

Page 17: ...on above 2s to set your required swing angle When reaching your required angle release the button Note may not be available When air conditioner receives this signal the air conditioner will blow fan...

Page 18: ...indicator on indoor unit displays outdoor ambient temperature Note Outdoor temperature display is not available for some models At that time indoor unit receives signal while it displays indoor set te...

Page 19: ...ed on the remote controller After this function is set the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature...

Page 20: ...ncrease or decrease 1min Hold or button 2s later the time will change quickly until reaching your required time resumes displaying Cancel TIMER ON Under the condition that TIMER ON is started up press...

Page 21: ...e remote controller won t send signal Sleep function and 8 heating function can t operate at the same time If 8 heating function has been set under cooling mode press sleep button will cancel 8 heatin...

Page 22: ...rection 2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstal...

Page 23: ...enance WARNING Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do n...

Page 24: ...pen panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean f...

Page 25: ...sal method 1 Check whether air inlets and air outlets are blocked 2 Check whether air switch plug and socket are in good condition 4 Check whether mounting bracket for outdoor unit is damaged or corro...

Page 26: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Page 27: ...perature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper at...

Page 28: ...g mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or turned off just now The noise is the so...

Page 29: ...r restarting the unit If not please It can be eliminated after restarting the unit If not please It can be eliminated after restarting the unit If not please It can be eliminated after restarting the...

Page 30: ...At least 30cm At least 300cm At least 200cm Space to the floor Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obs...

Page 31: ...y make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is...

Page 32: ...high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circu...

Page 33: ...the supply cord is damaged it must be replaced by the manufacturer its 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The app...

Page 34: ...e Wall Space to the wall above 150mm Space to the wall above 150mm 55mm Rear piping hole 12K 09K Left Wall 55mm Right Mark in the middle of it Level meter Rear piping hole Wall Space to the wall above...

Page 35: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left...

Page 36: ...in the indoor drain hose in order to prevent condensation The plastic expansion particles are 1 Open the panel remove the screw on the wiring cover and then take down the cover wiring cover screw pane...

Page 37: ...should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the s...

Page 38: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Page 39: ...t least 3cm above the floor in order to install drain joint For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansio...

Page 40: ...rol wire only for cooling and heating unit to the wiring terminal according to the Note the wiring board is for reference only please refer to the actual one 09 12K for some model 09 12K for some mode...

Page 41: ...e outlet pipe hole of indoor unit Slant the drain hose slightly dow nwards The drain hose can t be The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U s...

Page 42: ...If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and re...

Page 43: ...er cord follow the speci cation It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insuf cient cooling heating capacity The dust and sundr...

Page 44: ...requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amo...

Page 45: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Page 46: ...n suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the po...

Page 47: ......

Page 48: ...66129925451...

Reviews: