DC Inverter U-match Series Floor Ceiling Type Unit
5
3.2.2 Outdoor Unit
①
. Install the unit where it will not be tilted by more than 5°.
②
. During installation, if the outdoor unit has to be exposed to strong wind, it must be fixed securely.
If possible, do not install the unit where it will be exposed to direct sunlight. (If
necessary, install a blind that does not interfere with the air flow.)
(1). Install the outdoor unit in a place where it will be free from being dirty or
getting wet by rain as much as possible.
(2). Install the outdoor unit where it is convenient to connect with the indoor
unit.
(3). Install the outdoor unit where the condensate water can be drained out
freely during heating operation.
(4). Do not place animals and plants in the path of the warm air.
(5). Take the air conditioner weight into account and select a place where noise
and vibration are small.
(6). Install the outdoor unit where is capable of withstanding the weight of the
unit and generates as less noise and vibration as possible.
(7). Provide the space shown in Fig. 3.2, so that the air flow is not blocked. Also
for efficient operation, leave three of four directions of peripheral
constructions open.
Fig. 3.2
3.3 Connection Pipe Requirement
The maximum length of the connection pipe is listed in the Table below. Do not place the units
between which the distance exceeds the maximum length of the connection pipe.