![Kinghome GJC22BN-D3NRNC5P Owner'S Manual Download Page 34](http://html1.mh-extra.com/html/kinghome/gjc22bn-d3nrnc5p/gjc22bn-d3nrnc5p_owners-manual_1970314034.webp)
NOTE: Consult local building codes prior to installation,
This air conditioner has a slide-out chassis, so that it can be installed through an outside wall as
Max wall thickness
Inside Frame Height:
Inside Frame Width:
18 " (47.9cm)
7/8
26 " (67.9cm)
3/4
Side louvers must never be blocked.
IMPORTANT:
All parts needed for Thru-The-Wall Installation are provided,except a wood frame, shims,
and 10 wood screws ( #
construction at ends of windows,
and under truss-bearing points, etc.
can be installed,
10-1" long minimum). Select a wall surface that:
NOTE:
81/4"
or a qualified carpenter.
Selec t wall locatio n
Prepare wall
1. does not support major structural loads such as the frame
stucco veneer). Working from inside
the room, find wall
your model listed above.(Measure
Frame depth should be the same as wall thickness. Fill in the space
from the opening to the studs with wood spacers, as shown.
dry wall.
stud nearest the center of area where air conditioner will be installed (by
sounding wall, or by magnetically finding nails).
in FIG. 1.
FIG. 1
FIG. 2
1. Prepare wall in frame construction (including brick and
4. Build a wooden frame with the INSIDE dimensions of
5. Nail framd to spacers to spacers with front flush with
Carefully measure and cut an opening with the following dimensions depending on your
model. See FIGS. 1and 2.
of
material used.
WIDTH "X" = inside model width plus twice the thickness
HEIGHT "Y" = inside model height plus twice the thickness of framing
material used.
2.Cut or knock out a hole on each side of center stud.
3. Measure between inside edges of every other stud as shown
2. does not have plumbing or wiring inside.
3. i s near existing electrical outlets, or where another outlet
of installed air conditioner.
5. allows unblocked airflow from rear sides and end (outside
)
4. faces, and is not blocked to the area to be cooled.
3-3/8" MIN
(8.6 cm)
NAIL SPACERS TO STUDS
LEVEL
Inside
Frame
Height
Inside
Frame
Width
UP TO
8-1/2"
X
specified below:
framing
t wice remember...)
Thru-The-Wall Installation
Summary of Contents for GJC22BN-D3NRNC5P
Page 32: ...28...