background image

Figure 4.1 

KTW INSTALLATION INSTRUCTIONS 

 

     CAUTION! 

      Turn OFF all electrical power  

to install heater 

Model and Rating Label Location 

Total Amps 

Minimum AWG. Wire 

Size (Copper) 90 c 

Circuit Breaker 

or Fuse Size 

1 thru 12 

#14 

15 amp 

13 thru 16 

#12 

20 amp 

17 thru 25 

#10 

30 amp 

Selecting A Location For Your Heater: KT 

This heater has been designed to allow it to be recessed at floor 

level in the toe space of cabinets or under counters or at the base 

of walls.  When selecting the location, be sure the materials that 

will be located in the air heated by this heater (such as floor cover-

ings) will not distort or discolor at temperatures above 140°F 

(60ºC). DO NOT select a location directly beneath sinks or other 

work areas where people are likely to stand for extended periods of 

time. DO NOT install less than 6” (15cm) from vertical side walls or 

open edge of door. This heater must have an unrestricted airflow. 

DO NOT select a location where it is likely to be blocked by furni-

ture, throw rugs, etc. Be sure the location selected allows sufficient 

space for the heater as shown by Table 1. DO NOT locate this heat-

er in an area where combustible vapors, gases liquids, or excessive 

lint, dust or moisture is present. 

 

 

Specific to KT Series: 

The KT heater is intended for a toe space installation only. Other 

grilles are available for a flush surface mount installation that will 

trim out the wall can. The heater is designed to be installed in the 

toe-space of a cabinet with a minimum of 2” overhang to maximum 

7” of overhang. Shorter overhangs may overheat the floor where 

longer than 7” overhangs may overheat the cabinet door area. 

 

The wire and breaker sizing chart will give a general rule of installa-

tion size.  Consult an electrician if you are not knowledgeable about 

wiring codes.

 

 

Wire and Breaker Sizing:            

Table 2

 

 
 
 
 
 

 

 

WIRING: Branch Circuit Connection 

1.  Connect  heater only to the voltage, amperage and frequency           

specified on the nameplate. 

2.  heater only to the voltage, amperage and frequency           

specified on the nameplate. 

3.  Wiring procedures and connections shall be in accordance with 

all National and local codes having jurisdiction. 

4.  Remove the two screws holding the grille in place & set grille 

aside retaining the screws. 

5.  Removing the two screws holding the cover in place on each 

side of the heater will allow you access to the wiring compart-

ment. 

6.  A knockout of 1/2 inch conduit size (7/8 inch / 2.2cm) is pro-

vided in the back and side of the heater for power to enter. 

Provide proper conduit connectors for your flexible connec-

tions. 

7.  Attach ground to the green wire attached to wall case with a 

wire nut. 

8.  Assemble all covers on electrical and apply power. Test unit by 

turning thermostat up past room temperature. You will see a 

puff of smoke as the elements are energized and the fan turns 

on. This is a normal burn off of manufacturing lubricants and 

will dissipate in 5 minutes. 

9.  Heater will continue to run until the room temperature you set 

is reached and then turn itself off until the temperature drops 

again. 

 

CAUTION - High temperature.

 

Risk of fire

, keep electrical 

cords, drapery, furnishings, and other combustibles at least 3 feet 

(0.9 m) from the front of the heater as well as away from the side 

and rear. To reduce the risk of fire, do not store or use gasoline or 

other flammable vapors and liquids in the vicinity of the heater. 

   

 
   

   

ELECTRIC SHOCK  OR FIRE HAZARD

 

                                        

DANGER 

Figure 2 

Figure 4 

Factory Wiring Diagram                                     

Figure 5 

Minimum Horizontal Clearances

 

When placed in toe space  
of a cabinet only. Horizontal 

 

Min 0” 

Max 10” 

Depth of 

Space   

Front 

Top 

Bottom  Sides 

 

Cabinet  

Overhang 

36 in 

0 in 

0 in 

0 in     

 

91 cm  0 cm 

0 cm 

0 cm    KT Heater 

Floor 

Figure 3 

250 W 

500 W 

750 W 

Hi Switch 

LO SW 

TABLE 1 