22
Terminal block
The oven has an easily accessible terminal
block, which is meant to work with an electric
single-phase rate of 230 V (see Fig.).
FO 2159
The manufacturer disclaims any
responsability should all the safety
measures not be carried out.
Electrical connection
Before the appliance is connected:
1) check that the main fuse and the
domestic installation can support the
load;
2) check that the power supply is properly
earthed in compliance with the current
rules;
3) check the double pole switch used for
the electrical connection can be easily
reached with the appliance built in the
forniture unit.
The appliance is supplied with connection
cable provided with plug. The plug has to be
fitted into a proper socket.
In case of a direct connection to the mains,
it is necessary that you install a double pole
switch between the appliance and the
electricity supply, with a minimum gap of 3
mm. between the switch contacts and of a
type suitable for the required load in
compliance with the current rules.
The connection cable has to be placed in
order that, in each part, it cannot reach a
temperature 50 °C higher than the room
temperature.
Should the supply cable need to be
replaced, use only the following cable
types: - H05 RR-F; - H05 VV-F;- H07 RN-
F; -H05 RN-F; - H05 BB-F; - H05V2V2-F
(T90).
After the connection is carried out, test the
heating elements for about 3 minutes.