It is
extremely important
to verify the electrical power supply is the same voltage as the heater being installed.
240 and 120 Volt heaters are not interchangeable
. Powering a 240 Volt unit with 120 Volt supply wires will
reduce heater output by approximately 75%. Powering a 120 Volt unit with 240 Volt supply wires will destroy the
heater and voids all guarantee and warranties.
CAUTION:
Turn off power source supplying heater before attempting
any installation, maintenance or repairs. Lock or tag circuit breaker/fuse
panel door. Failure to do so could result in serious electrical shock, burns
or possible death.
WARNINGS:
To insure proper operation of this heater it should be a minimum
of 6 feet above the floor and no closer than 2½” below drywall ceiling
(6” vinyl or drop ceilings). Draperies should clear the front and the top of this
heater by 6”. Draperies hung below the heater should have a 2½” clearance.
Do not block the heater in any manner. Never paint the heater.
MAINTENANCE & WARRANTY
KCV SERIES
Cove
Heater
SAVE THESE INSTRUCTIONS
GENERAL INFORMATION
KING ELECTRICAL MFG. COMPANY • 9131 10TH AVENUE SOUTH • SEATTLE, WA 98108 • PH: 206.762.0400 • FAX: 206.763.7738 • www.king-electric.com
REV. 66447_9-26-18
Cove heaters are completely assembled and pre-wired. To prepare
the heater for installation, carefully check the voltage to be used is
the same as stated on the rating nameplate. Operating voltage can
not exceed 5% of nameplate voltage. Operating heater above listed
voltage ratings voids all gaurantees and warranties.
Following the guidlines herein listed will result in a maintenance-free heater. There are no moving parts or motors
to maintain. Periodic dusting of the front panel is all that is suggested.
The KCV Cove Heater carries a (2) warranty form date of installation. Please refer to the manufacturer’s warranty
statement for further information.
Diag. A