It is 

extremely important

 to verify the electrical power supply is the same voltage as the heater being installed.

240 and 120 Volt heaters are not interchangeable

. Powering a 240 Volt unit with 120 Volt supply wires will 

reduce heater output by approximately 75%. Powering a 120 Volt unit with 240 Volt supply wires will destroy the 
heater and voids all guarantee and warranties.

CAUTION:

 

Turn off power source supplying heater before attempting 

any installation, maintenance or repairs. Lock or tag circuit breaker/fuse 
panel door. Failure to do so could result in serious electrical shock, burns 
or possible death.

WARNINGS:

 

To insure proper operation of this heater it should be a minimum 

of 6 feet above the floor and no closer than 2½” below drywall ceiling 
(6” vinyl or drop ceilings). Draperies should clear the front and the top of this 
heater by 6”. Draperies hung below the heater should have a 2½” clearance. 
Do not block the heater in any manner. Never paint the heater.

MAINTENANCE & WARRANTY

KCV SERIES

 

Cove 

Heater

SAVE THESE INSTRUCTIONS

GENERAL INFORMATION

KING ELECTRICAL MFG. COMPANY  •  9131 10TH AVENUE SOUTH  •  SEATTLE, WA  98108  •  PH: 206.762.0400  •  FAX: 206.763.7738  •  www.king-electric.com

REV. 66447_9-26-18

Cove heaters are completely assembled and pre-wired. To prepare 
the heater for installation, carefully check the voltage to be used is 
the same as stated on the rating nameplate. Operating voltage can 
not exceed 5% of nameplate voltage. Operating heater above listed 
voltage ratings voids all gaurantees and warranties.

Following the guidlines herein listed will result in a maintenance-free heater. There are no moving parts or motors
to maintain. Periodic dusting of the front panel is all that is suggested.

The KCV Cove Heater carries a (2) warranty form date of installation. Please refer to the manufacturer’s warranty 
statement for further information.