background image

ECP

ECP

 

PROGRAMMING INSTRUCTIONS

ENERGY STAR

Technical support: (800) 603-5464 ext 111 / [email protected]

SAVE THESE INSTRUCTIONS

Program

Temp.

Monday - Friday

Saturday

Sunday

 

Morning wake-up program

 

Daily away from home program

 

Evening home program

 

Nightly sleep program

Program

Mo-Su

Temp.

6:00am

8:00am

6:00pm

10:00pm

70°

62°

70°

62°

Default Energy Star Schedule

Temp.

Temp.

Return

Sleep

Leave

Wake

Return

Sleep

Leave

Wake

Return

Sleep

Leave

Wake

Time

Time

Time

°F

°F

°F

°F

°F

°F

°F

°F

°F

°F

°F

°F

:

:

:

:

:

:

:

:

:

:

:

:

Use     or     to set day of the week.

2

1

Turn switch to “

DAY”.

Set D

Set D

ay and Time

ay and Time

1

Turn switch to 

“Mo-Fr” 

(Monday - Friday).

1

2

Set To Run

Set To Run

Press         to set first program-period 
of weekday. 

2

Turn switch to 

“RUN”

 to operate. 

1

2

Press      and       together for 8 seconds.

3

Adjusting the Differential

Adjusting the Differential

Turn switch to 

“TIME”

.

3

Use     or      to set hour and minute.

4

“ERR”

 will show if no data 

is input after 10 minutes. To 

continue, turn switch to “RUN” 

then back to previous position. 

Use     or      to set time for         .

3

4

Press         to set temperature setpoint. 

Use      or       to set           temperature.

5

Pressing          will alternate the display 
between time and temperature settings
for all 4 buttons.

6

Press         to set second program-period  
of weekday. 

4

Override Function

Override Function

5

Your Schedule

Your Schedule

Follow steps 3 - 5 to complete  
programming.

7

8

Press         to set third program-period 
of weekday. 

Follow steps 3 - 5 to complete  
programming.

9

10

Press         to set fourth program-period 
of weekday.

 

Follow steps 3 - 5 to complete  
programming.

11

Turn switch to 

“SAT” 

(Saturday).

12

Follow steps 3 - 5 to complete Saturday 
programming.

13

Turn switch to 

“SUN”

 (Sunday).

14

Follow steps 3 - 5 to complete Sunday 
programming.

15

3

Use either      or       to set differential.

The thermostat will memorize and use the 
new setting after 5 seconds.

The thermostat will memorize and use the 
new setting after 5 seconds.

4

This thermostat provides 2 manual temperature 
overrides.

Turn switch to 

“RUN”

1

TEMPORARY temperature change 

Use      or       to change temperature setting.

2

The thermostat will memorize and use
the new temperature setting after 5 seconds or 
until the next time-temperature begins.

3

To end the temporary override turn the switch 
away from 

“RUN”

 then back.

4

PERMANENT on HOLD temperature setting

Turn switch to 

“HOLD”

.

 

1

Use      or       to change temperature 
setting.

2

The thermostat will use the new setting after 
5 seconds until the user manually ends it.

3

To end the permanent on hold override turn
the switch away from 

“HOLD” 

to 

“RUN” 

or 

“Key Lock”

.

4

Wattage
100 to 1000W
1200 to 2000 W
2000 to 2750 W
3000 to 3840W

Suggested
Differential



6

Display Options / TAP Display Button

Display Options / TAP Display Button

Room Temperature / Day and Time / 
Setpoint Temperature Alternating

1

Room Temperature Only / No Alterations

2

DISPLAY

7

Batteries

Batteries

LCD display and relay are battery powered, not 
charged by line voltage. One year life is expected.

1

Wake

Wake

OK

OK

Wake

Return

Sleep

Leave

Leave

Return

Sleep

2

BAT LO

” showing on the LCD indicates time to 

replace the batteries.

Key Lock

This deactivates buttons on 
the front panel. Temperature 
can not be changed without 
switching back to RUN.

ECP programming.ai : 3/07

Key Lock

Key Lock

Key Lock

Key Lock

Key Lock

Key Lock

Key Lock

Day

Day

Day

Day

Day

Day

Time

Mo-Fr

Sat

Sun

Hold

Run

Return

Sleep

OK

Leave

Wake

Reset

Wake

Leave

OK

Sleep

Return

Run

Hold

Sun

Sat

Mo-Fr

Time

Day

Reset

Time

Mo-Fr

Sat

Sun

Hold

Run

Return

Sleep

OK

Leave

Wake

Reset

Time

Mo-Fr

Sat

Sun

Hold

Run

Return

Sleep

OK

Leave

Wake

Reset

Time

Mo-Fr

Sat

Sun

Hold

Run

Return

Sleep

OK

Leave

Wake

Reset

Time

Mo-Fr

Sat

Sun

Hold

Run

Return

Sleep

OK

Leave

Wake

Reset

Time

Mo-Fr

Sat

Sun

Hold

Run

Return

Sleep

OK

Leave

Wake

Reset

Disp

C

US

LISTED

UL

®

Summary of Contents for ECP Series

Page 1: ...g or wall panel heaters cove heaters or any line voltage resistance heating systems that do not have an electric motor over 1 3 hp OPERATION This precision electronic thermostat uses a very sensitive thermistor near the bottom to sense room air temperature sending the information on to the microprocessor As the temperature drops the information sent will indicate if heat is needed To reduce any un...

Page 2: ...he wires carefully into the junction box making sure no wires are pinched or will obstruct the screws mounting the thermostat Now attach the thermostat to the wall using the 6 32 Phillips head screws provided Replace cover Do not over tighten screws 8 Install AA batteries to start display Replace cover Batteries operate relay and display only they are not charged by voltage power and should last o...

Page 3: ...oom temperature by tapping the Up button There will be up to a 3 minute delay turning on You will hear a small click and Heater On will appear on the LCD the heater should now be on Turn the thermostat down by tapping on the Down arrow 8 Differential Adjustment Hold both temperature and buttons for 10 seconds The screen will go blank then show one digit This is the number of degrees that the therm...

Page 4: ...e the new setting after 5 seconds The thermostat will memorize and use the new setting after 5 seconds 4 This thermostat provides 2 manual temperature overrides Turn switch to RUN 1 TEMPORARY temperature change Use or to change temperature setting 2 The thermostat will memorize and use the new temperature setting after 5 seconds or until the next time temperature begins 3 To end the temporary over...