Instructions Manual Dispenser Rx Tablet and Capsule Counting Machine Edition v2.1
26
OPERATION: Correct Bottle Platform Adjustment
•
To adjust the
BOTTLE PLATFORM
first loosen the
CLAMPING HANDLE
to allow the
BOTTLE PLATFORM
free movement.
•
Using two bottles manually adjust the height of the
BOTTLE PLATFORM
using the
CLAMPING HANDLE
located on the right underside to achieve a small gap between the
underside of the funnel and the top of the bottle neck opening. Leaving a small gap of
between 2mm and 3mm between the underside of the funnel and neck opening of the
bottle facilitates easy placement and removal of bottles during operation.
•
Proceed to tighten the
CLAMPING HANDLE
once the
BOTTLE PLATFORM
is located in
the correct position.
Bottle Platform
Clamping Handle
Funnel
2mm to 3mm gap