King Tony 7DM1160 Manual Download Page 2

H

I

A

B

D

E

G

C

F

Overview for device :

• A - LCD
• B - Single measure
• C - Addition
• D - Subtraction
• E - Clear / power
• F - Functions : Single measure, 
        continuous measure, area, volume, 
        six indirectly height measurements, 
        stake-out, level, unit and setting
• G - Reference
• H - Receiving lens
• I - Laser emitted window

1

2

3

4

5
6

LCD

1

B

attery status 

2

M

easuring reference  

3

M

emory 

4

A

ngle 

5

. Measuring function 

6

M

easuring    

43

2.612 m

2.039 m

2.012 m

2.484 m

81°

1

2

● For the measurement from the rear edge of the measurer, 90% reflectivity 

surface (e.g., a white painted wall), low background illumination, operation 
temperature at 25

°

C. The tolerances apply from 0.5 meters to 10 meters 

with a confidence level of 95%. The maximum tolerance must add ±0.15 
mm/m between 10 meters to 30 meters and ±0.25 mm/m for distances 
above 30 meters into the count.

● The measurement from the rear of the measurer, apply with a target with 

18 to 100% reflectivity or intense ambient illumination, measuring within 
temperature at 25

°

C. The tolerances apply from 0.5 meters to 10 meters 

with a confidence level of 95%. The maximum tolerance may deteriorate 
to ±0.4mm/m between 10 meters to 30 meters and ±0.5mm/m for 
distances above 30 m and after.

● Apply with 100% reflective target, ambient light illumination is approxi-

mately 30,000 lux.

Battery & Power Management 

1. This laser distance meter uses 2 x AAA Batteries.
2. Remove the battery lid and install the batteries with the correct polarity.
3. The full battery icon          indicates that batteries are full.
4. If the battery icon          appears with one slot left, the laser distance meter 

can still measure approximately 600 times and prefer to place new 
batteries.

5. Replace batteries when the empty battery icon          flash on the screen.

7DM1160

Summary of Contents for 7DM1160

Page 1: ...nuous Measure Indirect Measure I Digital Level Unit 50 Records Screen Orientation Measure Reference Area Measure Volume Measure Stake out a a Indirect Measure II Indirect Measure III Indirect Measure IV Indirect Measure VI Indirect Measure V GLOBAL UNITS 8 s NO 7DM1160 FULL COLOR LASER DISTANCE METERS 60M 43 2 612 m 2 039 m 2 012 m 2 484 m 81 7DM1160 ...

Page 2: ...5 mm m for distances above 30 meters into the count The measurement from the rear of the measurer apply with a target with 18 to 100 reflectivity or intense ambient illumination measuring within temperature at 25 C The tolerances apply from 0 5 meters to 10 meters with a confidence level of 95 The maximum tolerance may deteriorate to 0 4mm m between 10 meters to 30 meters and 0 5mm m for distances...

Page 3: ... Mode In Area mode the laser distance meter calculates the result automatically after measuring all lengths 1 Tap to find the icon then enter to the mode 2 Follow instructions on the screen to measure all necessary lengths the area shows on the screen with length and width 3 Tap to return to the previous step Volume Measurements Mode 1 Tap to find the icon then enter to the mode 2 Follow instructi...

Page 4: ... the hypotenuse and length of the base The height summary shows on the screen with the length of the hypotenuse and base 4 Tap to return to the previous step Indirectly Height Measurement 3 1 Tap to find the icon then enter to the mode 2 Find the icon to enter to the indirectly height measurement mode 3 which measures the height difference of the two triangles with the same base 3 Press the measur...

Page 5: ...o find the icon then enter to the mode 2 Find the icon to enter to the indirectly height measurement mode 6 which measures the height difference of the two triangles with the same base but calculate by angles 3 Follow the instructions on the screen and measure the two lengths of the hypotenuse The height shows on the screen with the length difference of the hypotenuse and angle 4 Tap to return to ...

Page 6: ...igh to choose 2 Tap to find the icon then enter to the mode 3 Find the icon and press in the setting inside the application menu tap or to select the sound volume meter Length Area Volume m m m in 0 0 1 32 1 32in 1 16in 1 8in 10 33 P m feet inch inch inch inch 尺 0 0 1 32 Front Back Left Right Calibrate the Digital Level 1 You can always re calibration the accelerometer before use 2 Tap to find the...

Page 7: ...stall new batteries Err06 Out of working temperature Measure in an environment within specified working temperature Err07 Ambient light is too strong Measure in a darker place shadow target Code Description Solution Screen Orientation The laser distance meter rotates the screen between 0 and 90 1 Tap to find the icon then enter to the setting mode 2 Find the icon tap to turn on off auto rotation M...

Page 8: ...ied herein may result in laser radiation exposure 4 Never stare directly into the beam or aim the laser beams at others 5 The product contains semiconductor laser diodes with wavelengths of 650 nanometers 6 The total continuous output of the beams never exceeds 1 0 milli watts Technical data Display Color LCD Measuring Range 0 05 m 60 m Resolution 0 001 m Accuracy 1 5 mm Laser Type 650 nm Class II...