background image

 

5.

 

Schedule: SMS Instruction Set 

Function 

SMS command 

Remarks 

Equipment time calibration 

Pa TEL + 
equipment number# 

The first time or replace the phone 
card. That needs it. 

Modify password 

Current paP 
+new password 

Default password: 1234 

Set user number 

Pa A + serial 
number# + user number# 

Serial number is 001~200; permanent 
license 

Set user number 

Pa A + serial 
number# +user number# 
+ start time# + end time#   

Can call into to control relay during 
start time and end time. 

Delete user number 

Pa A + serial 
number## 

 

Query user number 
authorization time 

Pa A + serial 
number# 

 

Query user number 

Pa AL 

  xxx 

+ yyy

 

xxx, yyy = 001~200, yyy>=xxx 

Allow any number to control 
relay 

Pa ALL# 

 

Only user number to control 
relay 

Pa AUT# 

Default 

Set relay activity time 

Pa GOT + 
Activity time# 

Activity time: 000~999, unit: second 

Return SMS after relay 

close(on) 

Pa GON + ab# 
+ SMS content# 

a, b=0 or 1; (a corresponds to the first 
number; b corresponds to the number 
of incoming calls; 0: not to return, 1: to 
return) 

Return SMS after relay 
open(off) 

Pa GOFF + ab# 
+ SMS content# 

Not to return SMS after relay 
close(on) 

Pa GON## 

 

Not to return SMS after relay 
open(off) 

Pa GOFF## 

 

Control the relay close(on) 

Pa CC 

 

Control the relay open(off) 

Pa DD 

 

Query device status 

Pa EE 

 

Set interval reporting time 

Pa T# + Interval 
time# 

Interval time: 000~999 unit: hour 

Query interval reporting time 

Pa T# 

 

Query IMEI and version 

Pa IMEI# 

 

Set not call next authorize no. 
after answering 

PaCOFF# 
 

Default; If someone answer, then not 
call next authorize user 

Set continue to call next 
authorize no. even answering if 
without press a key 

PaCON# 
 

Press "#" on the phone to open the door 
and stop calling; 
Press "*" or "0~9" to stop calling, but 
not open the door. 

Set calling time 

PaCOT+ calling 
time 

Calling time: 0~65536, unit: second, 
default 60 

Set relay output normal open 

PaNO 

 

Set relay output normal close 

PaNC 

 

 

Summary of Contents for K6S

Page 1: ...ess control system it supports dial to open the door with free call charge can remote open the door for visitors very suitable for different office villas and public occasion User s Manual Ver 3 1 Date 2018 04 10 Download APP Apartment Intercom ...

Page 2: ...gain then recovery SMS commands can be used to query the current state of the host relay status and GSM signal value SMS can be regularly uploaded for the current state of the host to the first user number Use the clock on the module each time the host sends SMS to itself to correct the time 2 Host Overview Microphone Relay door indicator lamp relay close on relay open off Signal lamp GSM version ...

Page 3: ...owing letters are uppercase letters Password factory default is 1234 is not the message content Such as equipment time command 1234TEL13812345678 Each instruction will receive the corresponding information or action of the feedback from the device If you do not receive feedback indicate that the device did not receive the instruction please check whether the card is inserted and the card is valid ...

Page 4: ...ncoming to control relay Password ALL Set only user number available of incoming to control relay default Password AUT Set relay activity time Password GOT the activity time activity time is 000 999 Unit second The activity time is set to 000 default which means that the user will automatically recovery when the relay is activity for about 0 5 seconds The activity time is set to 999 which means th...

Page 5: ...ult Password GOFF11 Content of SMS 2 Set to return SMS to the first number not to the incoming number after the relay open Password GOFF10 Content of SMS 3 Set to return SMS to the incoming number not to the first number after the relay open Password GOFF01 Content of SMS 4 Set not to return SMS after the relay open Password GOFF SMS control relay close on Password CC SMS control relay open off Pa...

Page 6: ...device will continue to call next authorize number without pressing the key on the phone If press then open the door and stop calling next one Press or 0 9 will not open the door and not call next authorize number Set calling time Password COT calling time Calling time 0 65536 unit second default 60 it means the calling will be hung up automatically once the calling time arrives 60s 0 means the ca...

Page 7: ...word GON ab SMS content a b 0 or 1 a corresponds to the first number b corresponds to the number of incoming calls 0 not to return 1 to return Return SMS after relay open off Password GOFF ab SMS content Not to return SMS after relay close on Password GON Not to return SMS after relay open off Password GOFF Control the relay close on Password CC Control the relay open off Password DD Query device ...