background image

Modbus IoT Gateway

BL101

BL101

User Manual

Revision: V1.0

Issue Date: 2021-6-1

King Pigeon Communication Co., Ltd

Website: www.iot-solution.com

Summary of Contents for BL101

Page 1: ...Modbus IoT Gateway BL101 BL101 User Manual Revision V1 0 Issue Date 2021 6 1 King Pigeon Communication Co Ltd Website www iot solution com ...

Page 2: ...ocument without written approval of King Pigeon Any violation will be subject to legal liability Disclaimer This document is designed for assisting user to better understand the device As the described device BL101 is under continuous improvement this manual may be updated or revised from time to time without prior notice This Modbus Gateway is mainly used for industrial data transmission over Eth...

Page 3: ...ard and SD Card Slots 15 2 4 Program Debugging Upgrading Interface 15 2 5 Device Grounding 15 2 6 4G Antenna 16 2 7 LED Indicator 16 2 8 RESET Button 17 2 9 COM Power Output Port 17 2 10 WAN LAN Port 18 3 Device Mounting 18 3 1 Wall Mounting 18 3 2 DIN Rail Mounting 19 4 Configurator Operation 19 4 1 Login to Configuration Software 19 4 1 1 Open Configuration Software 19 4 1 2 Search for Device 20...

Page 4: ...atapoints 33 4 2 5 4G Cellular Network Introduction 33 4 2 6 Alarms and Events Configuration 34 4 2 6 1 Alarm Points Configuration 34 4 2 6 2 Alarm Event Configuration 35 4 2 7 Task Plan Configuration 37 4 2 8 Data Service 38 4 2 8 1 Transparent Transmission 38 4 2 8 2 Modbus RTU to Modbus TCP 39 4 2 8 3 Modbus TCP Server 41 4 2 8 4 OPC UA 41 4 2 9 Cloud Platform Connection 42 4 2 9 1 MQTT Client ...

Page 5: ... 60 5 2 2 2 View Dat with KEPServerEX 6 60 5 2 2 3 OPC UA Configuration 61 5 2 2 4 View Data with KEPServerEX 6 62 5 2 2 5 Alibaba Cloud Configuration 63 5 2 2 6 View Data from Alibaba Cloud 64 5 2 2 7 HUAWEI Cloud Configuration 65 5 2 2 8 View Data from HUAWEI Cloud 67 5 2 2 9 AWS Configuration 68 5 2 2 10 View Data from AWS 69 5 2 2 11 King Pigeon Cloud via Modbus Configuration 70 5 2 2 12 View ...

Page 6: ...n be connected either through 4G cellular or Ethernet for high transfer speed and low latency On downstream it supports Modbus RTU Master and Modbus TCP Master on upstream it supports Modbus TCP MQTT OPC UA HUAWEI Cloud Alibaba Cloud AWS King Pigeon Cloud etc Users can connect various devices to cloud SCADA OPC UA and MES system with this gateway Mutiple platforms and host computers can be online ...

Page 7: ... King Pigeon Communication Co Ltd V1 0 www iot solution com Modbus to MQTT IoT Gateway BL101 1 2 Application Scenario 1 3 Packing List Before operating the device please make sure all below parts are in the package ...

Page 8: ...ion Co Ltd V1 0 www iot solution com Modbus to MQTT IoT Gateway BL101 1XBL101 Gateway 1x 4PIN 3 5mm terminal for power input 1x RS485 232 5PIN 3 5mm terminal for power output 1 x 4G SMA Cellular Network Antenna 2 x Wall mounting Clip Kit ...

Page 9: ...MQTT IoT Gateway BL101 1 x DIN Rail Clip Kit 1 x User Manual Softcopy in PDF format Note Please scan QR code to download 1 x Data Card Picking PIN 1 x Product Qualification Certificate 1 x Warranty Card Note If any of the above items are missing please contact King Pigeon Sales team ...

Page 10: ... switch can be acquisted Both network link and rate indicators are available Built in isolation transformer for up to 2KV electromagnetic insulation Support POE PD Powered Device for saving wiring cost Optional function Support TSL SSL encryption for data security Support router function to provide network for other devices Support 4G network with APN setting Ethernet network will be used first if...

Page 11: ...te 2400bps 115200bps Data Bit 7 8 Parity Bit None Even Odd Stop Bit 1 2 Port Protection ESD 8kV Contact 15kV Air EFT 2KV 40A 5 50ns Power Output Output Voltage 1 channel 9 36 V DC Equal to input power voltage SIM Card Slot Qty 1 Spec Drawer design Support 1 8V 3V SIM UIM card NANO Protection Inbuilt 15KV ESD protection SD Card Slot Reserved function Reserved for future development USB Port Qty 1 p...

Page 12: ...light if communication is over 4G network Off if no data communication TXD Flickering if device is transmitting data Off if there s no data transmitting RXD Flickering if device is receiving data Off if there is no data receiving Software Parameter Network Protocol IPV4 TCP UDP DHCP DNS IP Retrieving Static IP DHCP Transmission Support Transparent Data Transmission DNS Support Domain Name Resoluti...

Page 13: ...ondition Working 40 80 5 95 RH Storage 40 85 5 95 RH Others Case Material Metal Size 30mm 83mm 110mm L W H Protection IP30 Net Weight 291 2g Mounting Wall mounting DIN Rail mounting 1 6 Model Selection Model NO WAN LAN COM Default RS485 RS485 RS232 optional OPC UA 4G POE PD BL101 X Optional BL101E X X Optional BL101UA X Optional 2 Hardware Introduction 2 1 Outline Dimension Unit mm ...

Page 14: ...ge 14 of 76 King Pigeon Communication Co Ltd V1 0 www iot solution com Modbus to MQTT IoT Gateway BL101 2 2 Power Source Input 2 optional power source input channels support 9 36VDC voltage input support ...

Page 15: ...ed off Insert SIM card picking PIN to the small hole of card slot and eject the card slot with tiny force Note Place the device like above picture to insert remove SIM card 2 4 Program Debugging Upgrading Interface DEBUG USB port is for program debugging DOWNLOAD USB port is for program upgrading 2 5 Device Grounding Before connecting the device please do equipment grounding with grounding screw t...

Page 16: ...ce faulty NET Ethernet 4G Network Flickering Ethernet network On 4G network Off No communication TX Data Transmitting Flickering Serial port is transmitting data Off No data transfer from serial port RX Data Receiving Flickering Serial port is receiving data Off No data is received in serial port Note RUN indicator will be on if device is powered If it s not on please check whether there s reverse...

Page 17: ...or about 10 seconds until RUN indicator is off Then Gateway will restart and return to factory setting 2 9 COM Power Output Port RS485 RS232 Power Output Terminal Item Description VOUT Power Output Positive Terminal VOUT Power Output Negative Terminal B RX RS485 Data B Receiving Data A TX RS485 Data A Transmitting Data GND Grounding Note Power output voltage is equal to power input voltage 9 36VDC...

Page 18: ...101 2 10 WAN LAN Port 3 Device Mounting BL101 Gateway can be placed on desk mounted on the wall and DIN Rail 3 1 Wall Mounting Wall Mounting Ethernet Port Indicator Color Status Description Rate Green On 100Mbps mode Off 10Mbps mode Link Yellow On Connected Flickering Transferring data Off Disconnected ...

Page 19: ... the same local area network If it s necessary to connect the gateway to PC directly use standard cross network cable to connect through BL101 LAN port If BL101 is connected to PC directly PC IP must be specified to 192 168 3 1 as default LAN IP of gateway is 192 168 3 1 from factory setting Note WAN port IP is retrieved automatically LAN port IP is 192 168 3 1 from factory setting 4 1 1 Open Conf...

Page 20: ...h for Device Click Device Search to get all devices which are in the same local area network with PC If no device is found please follow the procedure on the right notice box to check the root cause Below is the example of connecting Gateway BL101 with switch through WAN A device with IP 192 168 1 165 is searched out ...

Page 21: ...lution com Modbus to MQTT IoT Gateway BL101 4 1 3 Connect Gateway Device Double click the device to be configured For example double click device with IP 192 168 1 165 Reading success message will be shown in prompting box Click confirm to enter configuration page ...

Page 22: ...File Import gateway configuration file Export Configuration File Export gateway configuration file Read Data Read logged in BL101 gateway configuration parameters Save Data Save all configuration parameters by clicking it Monitoring Monitor connected device value Log System running log If device issue click save log to send it to specified email box Language Click it to change language to English ...

Page 23: ...icates MQTT Client One is connected Gray indicates MQTT Client One is unconnected MQTT Client Two Online Status Red indicates MQTT Client Two is connected Gray indicates MQTT Client Two is unconnected Ali IOT Cloud Online Status Red indicates Ali Cloud is connected Gray indicates Ali Cloud is unconnected HUAWEI IOT Cloud Online Status Red indicates HUAWEI Cloud is connected Gray indicates HUAWEI C...

Page 24: ...l pop up for configuration Serial Port Attributes Item Description Default Mode Selection Select mode Collect Transparent Transmission Modbus RTU to Modbus TCP Collect Protocol Device Brand Modbus Modbus Device Model Modbus RTU Modbus RTU Serial Port Settings Baud Rate Select from 2400 4800 9600 19200 38400 57600 115200 9600 Stop Bit Select 1Bit or 2Bit 1Bit Data Bit Select 7Bit or 8Bit 8Bit Parit...

Page 25: ...M port configuration 4 2 2 2 Add COM Port Devices Right click COM1 and click Add to add new data logging device Device configuration box will pop up For the added device double click it to show device configuration information Right click to delete device Note Maximum 50 Modbus RTU devices data can be collected through COM ...

Page 26: ...ght click the added datapoint to delete it Double click the datapoint to edit it To add more datapoints right click the box and perform the same procedures Device Information Item Description Default Device Name Name of Data Collecting Device Device Properties Station ID Data Collecting Device Modbus Communication Address 16 bit Data Type Select AB or BA AB 32 bit Data Type Select ABCD DCBA BADC C...

Page 27: ...t Variable Unit Datapoint unit Address Type Select datapoint Modbus function code 01 read holding coil 02 read input coil 03 read holding register 04 read input register Starting Address Datapoint address Data Type Select from Bool 16 bit unsigned integer 16 bit signed integer 32 bitunsigned integer 32 bit signed integer 32 bit single precision floating point Add Number Datapoint qty ...

Page 28: ...y where datapoints are stored Boolean 0 2000 addresses Numeric 0 2000 addresses MQTT flag Datapoint MQTT mark can be any mark OK Confirm datapoint setting Cancel Cancel datapoint setting Right click datapoint to delete it and double click it to edit it 4 2 3 LAN Port Introduction 4 2 3 1 LAN Port Attributes Configuration Double click LAN port to enter setting page Factory default IP of LAN is 192 ...

Page 29: ... Routing Green indicates routing function is enabled Gray indicates routing function is turned off IP Address LAN port IP Address MAC LAN port MAC OK Confirm LAN port Setting Cancel Cancel LAN port setting 4 2 3 2 Add LAN Port Device Right click LAN and clik Add to enter device configuration page Device can be connected directly with Gateway BL101 through LAN or through switch which is connected w...

Page 30: ...uration Item Description Device Name Name of Device to connect through LAN Device IP Set IP Address of LAN port device Device Port Set LAN device port Device Brand Modbus Device Model Modbus TCP Station ID LAN port device Modbus communication address 16 bit Data Type Select AB or BA 32 bit Data Type Select ABCD DCBA BADC or CDAB ...

Page 31: ...d datapoints of LAN port device Add COM Device Datapoint 4 2 4 WAN Port Introduction 4 2 4 1 WAN Port Attributes Configuration Double click WAN to enter configuration box WAN Port Configuration Item Description Auto IP Green indicates auto retrieving IP Gray indicates IP is specified IP Address Current IP Address of WAN Port Subnet Mask Current WAN Subnet Mask Gateway Current WAN Gateway Address M...

Page 32: ...ay BL101 Cancel Cancel WAN port setting 4 2 4 2 Add WAN Port Device Right click WAN and then click add to enter device configuration page More devices can be connected with switch connecting WAN port Note Total 50 Modbus TCP devices can be connected through LAN and WAN WAN Port Device Configuration ...

Page 33: ... bit Data Type Select AB or BA 32 bit Data Type Select ABCD DCBA BADC or CDAB OK Confirm WAN port device setting Cancel Cancel WAN port device setting 4 2 4 3 Add WAN Port Device Datapoints Follow the same procedure of adding datapoints for COM port device to add datapoints of WAN port device Add COM Port Device Datapoints 4 2 5 4G Cellular Network Introduction Double click 4G to enter APN setting...

Page 34: ...ess Point Name of SIM card cellular network User Name User Name of SIM card cellular network Password Password of SIM card cellular network 4 2 6 Alarms and Events Configuration Double click Alarms and Events to enter setting box Alarm points actions and alarm recovery actions can be set according to requirement 4 2 6 1 Alarm Points Configuration ...

Page 35: ...alarm value of numeric datapoints Low Limit Low limit alarm value of numeric datapoints Digital Alarm Type Select from digital alarm mode Normally Open or Normally Close Alarm ACK Time Within alarm acknowledge time if data will recover to normal value no alarm will be triggered Otherwise it will generate alarm OK Confirm alarms and events setting Cancel Cancel alarms and events setting 4 2 6 2 Ala...

Page 36: ...T Gateway BL101 Event Configuration Item Introduction Write Point Name Write Point Name is generated based on selected datapoint Click Add select datapoint and click OK to confirm Double click datapoint to view its attributes Write Value Write datapoint value For Boolean value select 1 or 0 ...

Page 37: ... click Task Plan to enter configuration box Right click the box and click Add to enter configuration box Task Plan Configuration Item Description Task Name Name of Task Plan UTC Time Set time to perform the planned task UTC time Week Set week day to perform the planned task Write Point Name Write Point Name will be generated based on selected ...

Page 38: ...ck OK to confirm Double click datapoint to view its attributes Write Value Write datapoint value For Boolean value select 1 or 0 OK Confirm Task Plan setting Cancel Cancel Task Plan setting 4 2 8 Data Service 4 2 8 1 Transparent Transmission Set COM mode to Transparent Transmission set COM parameters and then configure Transparent Transmission parameters ...

Page 39: ...t transmission server IP Monitoring Port Server Port If BL101 is used as server input monitoring port If BL101 is used as client input server port Login Message Data Package of logging in to server Login ACK Message Data Package of server response to login Heatbeat Message Heatbeat Data Package to keep connection Heatbeat ACK Message Data Package of server response to heartbeat Heatbeat Interval C...

Page 40: ...bus TCP Configuration Item Description Serial Port Choice COM1 Mode Selection TCP Server Gateway can only be TCP Server Select Network Port Select WAN or LAN Monitoring Port Input port of monitoring BL101 Gateway required OK Confirm Modbus RTU to Modbus TCP configuration Cancel Cancel Modbus RTU to Modbus TCP configuration ...

Page 41: ...r is enabled permanently Only configure Ethernet port and monitoring port Modbus TCP Server Configuration Item Description Ethernet Port Select WAN or LAN Port Input gateway monitoring port required OK Confirm Modbus TCP Server setting Cancel Cancel Modbus TCP Server setting 4 2 8 4 OPC UA BL101 Gateway supports OPC UA protocol and provides data as OPC UA server Note Only the model which supports ...

Page 42: ... Gray indicates login with Account and Password User Input User Name Password Input User Password Security Policy Encryption policy Select none basic256 basic128rsa15 or basic256sha256 Certificate OPC UA certificate select file to upload PrivateKey OPC UA encryption key select file to upload OK Confirm OPC UA setting Cancel Cancel OPC UA setting 4 2 9 Cloud Platform Connection BL101 Gateway suppor...

Page 43: ...oint TAG001 of COM Device 1 is published and other datapoints are not published Note Datapoint box is blank in default which means all datapoints will be published in default If multiple topics are published only one topic datapoint box can be blank Other topic datapoints must be selected MQTT Client One Configuration Item Description Enable Green indicates MQTT Client One is enabled Gray indicate...

Page 44: ...T to identify message channel of sending valid load data Wildcard can t be included in publishing message topic name Click Add to add more public topics Click Delete to delete Public Topic Uploading Interval Cycle time of MQTT data sending Default is 30s MQTT Data Re transmission Enable data re transmission Green indicates offline data will be transmitted once network recovers Gray indicates offli...

Page 45: ...eName as the one in Ali Cloud See below illustration Device Click DeviceSecret to view it DeviceSecret Set the same DeviceSecret as the one in Ali Cloud See below illustration Device Click DeviceSecret to view it Region Select Alibaba Cloud Region default is East China 2 Shanghai Root Certificate Select file to upload Need to select certificate X 509 first Client Certificate Select file to upload ...

Page 46: ...Cloud supports uploading certain datapoints of each Service ID Right click the box and click Add to enter datapoint dialog box Select the datapoint to upload and click OK to confirm it Double click the datapoint to view its attributes Note Datapoint box is blank in default which means all datapoints will be uploaded If there re multiple Service IDs only one Service ID datapoint box can be blank Da...

Page 47: ...rver IP Domain Name Select connecting to HUAWEI Cloud via MQTT to enter console Click Overview to get server IP address of device connection Server Port Default is 1883 input 1883 for connecting with Secret Key Input 8883 for connecting with Certificate Required Secret Key X 509 Default is connecting with Secret Key Click it to move the button on the right for connecting with Certificate Device ID...

Page 48: ...le to upload Need to select certificate X 509 first Client Secret Key Select file to upload Need to select certificate X 509 first Service ID Set the same Service ID as the one in HUAWEI Cloud IOT Platform Products Add Service Service ID Multiple Service IDs are supported Automatic Data Upload Cycle Cycle time of data uploading Default is 30s MQTT Data Re transmission Green indicates offline data ...

Page 49: ...ox can be blank For other topics datapoints for publishing must be selected AWS Configuration Item Description Enable Green indicates AWS is enabled Gray indicates AWS is disabled Default is disabled Server IP Domain Name Input ASW Connection Endpoint Enter Console click Things and then click Interact to get it Server Port 8883 Required Item Name Input Thing ARN ...

Page 50: ...the same topic when creating rules in AWS cloud It s the topic used for MQTT publishing message Click Add to create more Publish Topics Select Publish Topic and click Delete to delete it Automatic Data Upload Cycle Cycle time of data uploading Default is 30s Datapoint Publishing Selection Default is blank box with all datapoints to be published Right click the box and click Add to select datapoint...

Page 51: ...ntact King Pigeon sales to get the serial number if required to connect to King Pigeon cloud User Name MQTT Password MQTTPW Subscribe Topic King Pigeon Device Serial Number Publish Topic King Pigeon Device Serial Number Automatic Data Upload Cycle Cycle time of data uploading Default is 30s MQTT Data Retransmission Green indicates offline data will be transmitted once network recovers Gray indicat...

Page 52: ...n Cloud via Modbus is disabled Server IP Domain Name modbus dtuip com Server Port 6651 Required Modbus Station ID Set Modbus communication address of this Gateway device Login Message Input device serial number issued by King Pigeon Contact King Pigeon sales to get the serial number Login ACK Message Server acknowledges login messages Not necessary for King Pigeon Cloud Heatbeat Message Q Heatbeat...

Page 53: ...0T and collects its data through Modbus RTU protocol BL101 LAN port connects network switch N81 and multi functional RTU S475 connects N81 switch S475 data is collected through Modbus TCP protocol BL101 WAN port connects 4G industrial Router R40 LAN port Router R40 provides network to BL101 Gateway The collected data is uploaded to various cloud platforms 5 1 Device Connecting Diagram ...

Page 54: ...ts 5 2 1 1 COM Port Configuration COM port collects M140 data through Modbus RTU Configure COM port like below 1 Double click COM1 to enter configuration window 2 Mode Selection Collection 3 Device Brand Modbus Device Model Modbus RTU 4 Baud rate Stop bit Data Bit and Parity Bit will be set the same as that in M140T RS485 port 5 Click OK to confirm Note Click Save Data Gateway will restart automat...

Page 55: ... device name for example set M140T as device name 3 Input device modbus adress for example if M140T Modbus ID is 1 put 1 4 Select Type of data to be collected 5 Click OK to confirm adding M140T 6 Click COM1 to view the added device M140T If more devices to be added perform the same procedures as above Step 1 5 Note Click Save Data Gateway BL101 will restart automatically After restarting M140T is ...

Page 56: ...h are coil type 5 Read write Type Automatic identifying read write type according to Address Type 6 Variable Unit Input any required unit 7 Starting Address Input datapint register address for example DO1 register address in M140T is 0 input 0 8 Adding Qty if consecutive addresses are collected the same function code can multiply be collected 9 Modbus Mapping Address Input the address where the co...

Page 57: ...IP then LAN port must enable DHCP 3 Routing Enable network rounting function Default is disabled For example S475 data will be collected without network requirement then disable routing function 4 IP Address defaut is 192 168 3 1 the IP addresses assigned to LAN port devices must be within the range It can be changed according to requirement For example S475 is set to auto retrieving IP and the ra...

Page 58: ...Thus input S475 IP 192 168 3 125 4 Device Port input LAN port device port For example S475 Modbus TCP port is 502 Thus put 502 5 Device Brand Modbus Device Model Modbus TCP BL101 collects S475 through LAN port through Modbus TCP protocol 6 Station ID 1 S475 Modbus ID is 1 7 Select Data Type For example S475 power source and temperature humidity data is 16 bit AB type 32 bit data is not collected T...

Page 59: ...ress 24 Datapoint temperature register address in S475 is 24 8 Adding Qty If consecutive addresses to be collected the same function code can collect it simultaneously 9 Ratio set the ratio to be multiplied or minified for uploading to cloud 10 Modbus Mapping Address 0 S475 temperature data is saved in register address 0 of BL101 Modbus mapping address can be any from 0 to 2000 and it can t be rep...

Page 60: ... MQTT Thus it will not be described here 5 2 2 1 Modbus TCP Server Configuration 1 Doubel click Modbus TCP Server to enter configuration box 2 Ethernet Port Select WAN In this example industrial router R40 is connected through WAN Click WAN to view its IP address 192 168 1 197 3 Port This gateway is used as Modbus TCP Server monitoring port Input any port within range 1 65535 For example put 502 4...

Page 61: ... like SCADA MES PCs Below example is simulating KEPServerEX 6 as host computer to collect BL101 data 5 2 2 3 OPC UA Configuration 1 Double click OPC UA to enter configuration box 2 Click Enable to enable green color OPC UA Default is disabled gray color 3 Ethernet Port Select WAN This example is connecting router R40 through WAN ...

Page 62: ...ty Policy Select connection encryption policy This example is connecting without encryption thus select None 8 Certificate PrivateKey This example is connecting without encryption then it s not necessary to upload certificate and privatekey 9 Click OK to confirm OPC UA configuration 10 Click Save Data Gateway will restart automatically Afer device restarting OPC UA is configured successfully 5 2 2...

Page 63: ...ina 2 Shanghai 8 Root Certificate Upload root certificate if connecting with certificate is enabled 9 Client Certificate Upload client certificate if connecting with certificate is enabled 10 Client Secret Key Upload client secret key if connecting with certificate is enabled 11 Automatic Data Upload Cycle Cycle time of data uploading default is 30s 12 Datapoint Uploading Selection select the data...

Page 64: ...Page 64 of 76 King Pigeon Communication Co Ltd V1 0 www iot solution com Modbus to MQTT IoT Gateway BL101 5 2 2 6 View Data from Alibaba Cloud ...

Page 65: ...t is disabled gray 3 Server IP Domain Name input HUAWEI Cloud connecting address Login to HUAWEI Cloud enter console click overview to get server IP address 4 Server Port Default is 1883 for connecting with secrect key If connecting with certificate is selected server port is 8883 5 Secret Key X 509 click it to move the button on the right to set connecting with certificate In default the button i...

Page 66: ...enable green MQTT offline data retransmission once network resumes Gray indicates disabled 14 Datapoint Uploading Selection Right click the box to select datapoints for uploading In default the right box is blank with all datapoints to be uploaded For example select Service ID M140T datapoints to upload Right click the box to enter datapoint box select M140T datapoint DO1 and hold the mouse to dra...

Page 67: ...Page 67 of 76 King Pigeon Communication Co Ltd V1 0 www iot solution com Modbus to MQTT IoT Gateway BL101 5 2 2 8 View Data from HUAWEI Cloud ...

Page 68: ...I Cloud Below example is single topic with all datapoints to be published 1 Double click ASW to enter configuration box 2 Click Enable to enable green ASW default is disabled gray 3 Server IP Domain Name Input endpoint of connecting to AWS Login to ASW enter console click Things and click Interact to view it 4 Server Port 8883 5 Item Name Input thing ARN Click Details of Thing to view ARN in AWS 6...

Page 69: ...he topic It s iot topic thus input iot topic 11 Automatic Data Upload Cycle Cycle time of uploading data default is 30s 12 Datapoint Uploading Selection Select datapoint to upload in the right box Default is blank box with all datapoints to be uploaded 13 Click OK to confirm AWS configuration 14 Click Save Data Gateway will restart and AWS is enabled successfully Open configuration software and lo...

Page 70: ...ssage Input device serial number issued by King Pigeon 7 Login ACK Message Not necessary for King Pigeon cloud connection 8 Heatbeat Message Q Automatic filling in default 9 Heatbeat ACK Message A Automatic filling in default 10 Heatbeat Interval Set cycle time of sending heatbeat message Default is 60s 11 Click OK to confirm the configuration 12 Click Save Data Gateway will restart and King Pigeo...

Page 71: ...Page 71 of 76 King Pigeon Communication Co Ltd V1 0 www iot solution com Modbus to MQTT IoT Gateway BL101 5 2 2 12 View Data from King Pigeon Cloud via Modbus ...

Page 72: ...ber issued by King Pigeon 9 Publish Topic Input device serial number issued by King Pigeon 10 Automatic Data Upload Cycle Cycle time of uploading data In default it s 30s 11 MQTT Data Retransmission Click it to enable green offline data retransmission once network resumes 12 Datapoint Uploading Selection Select the datapoint to upload in the right box In default it s blank with all datapoints to b...

Page 73: ...geon Cloud via MQTT 5 2 2 15 King Pigeon Cloud MQTT Message Format MQTT Client One MQTT Client Two and King Pigeon Cloud MQTT data formats are the same See below 1 Valid Load Data Format in device Publishing messages Publish Topic Serial Number Configured publish topic sensorDatas Boolean value flag REG001 Read write identification mark ...

Page 74: ...there s alarm recovery It s not included in scheduled automatically uploaded data time 1622700769 Time mark it s time stamp of data uploading addTime 2021 06 03 06 12 49 Time mark it s time of device data uploading retransmit enable Retransmission mark MQTT historical data Only appear when there s historical data retransmission It s not included in scheduled automatically uploaded data Note Read W...

Page 75: ...re 2 Valid Load Data Format in device Subscribing messages Subscribe Topic Serial Number Subscribe topic set in configuration software King Pigeon cloud message publishing topic is serial number sensor ID thus wildcard must be added for device Subscribing Topic so that cloud can publishing data for controlling sensorDatas sensorsId 211267 cloud sensor ID switcher 1 Data Type and Value flag REG001 ...

Page 76: ...cessary to upgrade firmware for any new requirements 7 Warranty Term 1 Warranty period is 1 year from the date of purchase If any quality issues within warranty period it will be repaired for free 2 Device fault caused by wrong operation is beyond warranty 8 Technical Support King Pigeon Communication Co Ltd Telephone 0086 755 29451836 Website www iot solution com ...

Reviews: