AMPERÍMETRO DE PINZA EN MILIAMPERIOS

MANUAL DE INS

TRUCCIONES

5-4 

Función luz de f

ondo

 

Cuando se presiona el botón con el símbolo de luz “

”, la 

luz de fondo se encenderá. Pr

esione el botón nuevament

para apag

ar la luz poster

ior. Si no se pr

esiona nuevament

el botón, la luz poster

ior se apagar

á automáticamente en 

unos 30 segundos después de haberla encendido.

6. INSTR

UCCIONES DE MEDICIÓN

6-1 Medición de AC

A y mAC

A

(1) Coloque el selector en el rango deseado. La cor

rient

e a 

medir debe estar dentr

o del rango de medición.

(2) Medición normal (v

er Fig. 1):

Presi

one la mani

ja de abertur

a de la pinza par

a abrir l

as 

mordazas de pi

nza del amperí

metro y l

uego ciér

rel

as sobre 

un solo conductor. El

 val

or de la c

orrient

e medida se mues

tra 

en la pant

alla. La cor

rient

e de fuga a ti

erra o c

ualesqui

er 

pequeña corrient

e alter

na (CA) que c

ircul

e a trav

és del c

able 

a tier

ra se pueden medi

r mediant

e este método.

NO

TA

: Mantener el cable en el centr

o de la pinza 

propor

cionará r

esultados de pr

ueba más precisos cuando 

haga mediciones de cor

rient

e. Cero medidor par

a medir 

con precisión cir

cuitos de miliamperios ba

jos.

(3) Medición de corrient

e de fuga desbalanceada 

 

(ver F

ig. 2):

Abr

ace con la pinza todos los conductores e

xcep

to el 

cable a tierra. El v

alor de la corrient

e desbalanceada 

medida aparecer

á en la pantalla. Ant

es de esta medición 

desconecte del amperíme

tro cualquier conductor de 

prueba, por segur

idad.

En algunos casos donde sea difícil leer la pantalla, pr

esione 

el botón “

HOLD

” (ret

ención) y lea el result

ado después de 

quitar la pinza de los conductor

es.

Fig. 1 Medición nor

mal:

INC

ORRECTA                            C

ORRECTA

Fig. 2 Medición de cor

rient

e de fuga desbalanceada:

LO

AD

(carga)

LO

AD

(carga)

Sistema tr

ifásico -3 cables

Sistema monof

ásico - 2 cables

Summary of Contents for 42095

Page 1: ...KING 95 CLAMP METER INSTRUCTION MANUAL True RMS Milliamp Clamp Meter 42095 3131884...

Page 2: ...10 C to 60 C 14 F to 140 F 80 RH Altitude Up to 2000 meters Pollution Degree 2 Explanation of Symbols Attention refer to operation instructions Approvals TABLE OF CONTENTS 1 SAFETY INFORMATION 3 2 GE...

Page 3: ...eter will power itself off to save battery life This function can be disabled by pressing and holding the HOLD button and powering on the unit Over Load When the applied signal is larger than the maxi...

Page 4: ...uracy 600 0 0 1 1 0 2dgts 6 000K 0 001K 60 00K 0 01K 600 0K 0 1K Range Buzzer Function Ohm 45 4 DESCRIPTION 4 1 Description of the display Auto power off indication Polarity indication Low battery ind...

Page 5: ...ys To deactivate the LPF feature press and hold the LPF button for 2 seconds The meter will return to normal mode of operation The Cut Off frequency of the low pass filter is about 160Hz with attenuat...

Page 6: ...ent value is shown on the display Earth leakage current or any small AC current that flows through a ground wire can also be measured by this method NOTE Keeping the cable in the center of the clamp w...

Page 7: ...display 6 3 DCV Measurement Switch the main function selector to V range Connect the red test lead to the terminal and the black lead to the COM terminal Measure the voltage by touching the test lead...

Page 8: ...strument the battery symbol will appear on the LCD display and the batteries should be changed Before changing the batteries switch the main dial to OFF and disconnect test leads Open the back cover u...

Page 9: ...42 N Central Drive O Fallon MO 63366 www kinginnovation com 800 624 4320 MADE IN CHINA REV E 11 20 2020 King Innovation O Fallon MO 63366 42 N Central Drive www kinginnovation com 800 624 4320 HECHO...

Page 10: ...to adecuado aparece el s mbolo de bater a en la LCD Antes de reemplazar las bater as coloque el dial principal en OFF apagado y desconecte los conductores de prueba Abra la cubierta posterior con un d...

Page 11: ...taje de corriente directa VCD Cambie el selector de funci n principal al rango V Conecte el conductor de prueba rojo al terminal y el conductor de prueba negro al terminal COM Mida el voltaje tocando...

Page 12: ...ntalla La corriente de fuga a tierra o cualesquier peque a corriente alterna CA que circule a trav s del cable a tierra se pueden medir mediante este m todo NOTA Mantener el cable en el centro de la p...

Page 13: ...o bajo hasta que aparezca el s mbolo Para desactivar la funci n filtro de paso bajo mantenga presionado el bot n LPF filtro de paso bajo por 2 segundos El amper metro regresar al modo de funcionamient...

Page 14: ...1 0 2 d gitos 6 000K 0 001K 60 00K 0 01K 600 0K 0 1K Rango Funci n de indicador ac stico Buzzer Ohm 45 4 DESCRIPCI N 4 1 Descripci n de la pantalla Indicaci n de apagado autom tico Indicaci n de polar...

Page 15: ...horrar la bater a Esta funci n se puede deshabilitar manteniendo presionando el bot n HOLD y encendiendo la unidad Sobrecarga Cuando la se al aplicada es mayor que el m ximo para el rango en uso la pa...

Page 16: ...Explicaci n de s mbolos Atenci n Refi rase a las instrucciones de funcionamiento Aprobaciones NDICE 1 INFORMACI N DE SEGURIDAD 3 2 ESPECIFICACIONES GENERALES 4 3 ESPECIFICACIONES EL CTRICAS 5 3 1 Med...

Page 17: ...AMPER METRO DE PINZA KING 95 MANUAL DE INSTRUCCIONES Valor Real Ra z Media Cuadr tica True RMS Amper metro de pinza en miliamperios 42095 KING 95 CLAMP METER 3131884...

Reviews: