ASSEMBLY

Figure 1

Assembly 

 
Note: The following instructions use the      
Voyager DVR Drill Press model 58006 for the 
Safety Guard installation procedures. 
 

1) Remove the quick release nut (A) Fig.1. 
 
 
 
 
2) Loosen and remove the cap screw (A) Fig.2 

which secures the depth stop mount (B). 
Slide the depth stop mount downwards and 
remove it. 

 
 
 
 
 
 
 
3) Slide the depth stop mount (A) Fig.3 of the 

Safety Guard assembly onto the Drill Press 
quill. Make sure the depth stop rod (B) was 
positioned inside the bracket (C) first as 
shown in Fig.3. Secure the depth stop 
mount (A) to the quill using the same cap 
screw (A) Fig.2 removed previously. 

 
 
 
 
4) Reinstall the previously removed quick 

release nut (A) Fig.4 on the depth stop rod 
(B) as shown.