FIGURE 3

ELECTRICAL INFORMATION

WARNING!

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN

SERIOUS  INJURY!  ALL  ADJUSTMENTS  OR  REPAIRS  MUST  BE  DONE  WITH  THE  MACHINE  DISCONNECTED  FROM  THE

POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

POWER SUPPLY

        

WARNING:

YOUR JOINTER/PLANER MUST BE CONNECTED TO A

220V, 15 AMP. BRANCH CIRCUIT AND USE A 15 AMP. TIME DELAY

FUSE OR CIRCUIT BREAKER. FAILURE TO CONNECT IN THIS WAY

CAN RESULT IN INJURY FROM SHOCK OR FIRE.

Your Jointer/Planer must be properly grounded. Not all outlets are

properly grounded. If you are not sure if your outlet is properly

grounded, have it checked by a qualified electrician.

WARNING:

IF NOT PROPERLY GROUNDED, THIS JOINTER/

PLANER CAN CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN

USED IN DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE

POWER CORD IS WORN OR DAMAGED IN ANY WAY, HAVE IT

REPLACED IMMEDIATELY.

GROUNDING

This Jointer/Planer must be grounded. If it should malfunction or

breakdown, grounding provides a path of least resistance for electric

current, to reduce the risk of electric shock. This Jointer/Planer is

equipped with a cord having an equipment-grounding conductor and

grounding plug. The plug must be plugged into an appropriate outlet

that is properly installed and grounded in accordance with all local

codes and ordinances.

WARNING: 

TO MAINTAIN PROPER GROUNDING OF YOUR

JOINTER/PLANER, DO NOT REMOVE OR ALTER THE GROUNDING

PRONG IN ANY MANNER.

220V OPERATION

As received from the factory, your Jointer/Planer is ready to operate on

220V circuit. This Jointer/Planer is intended for use on a circuit that has

an outlet and a plug which looks like the one illustrated in Fig.1.

        

WARNING:

DO NOT USE A TWO-PRONG ADAPTER FOR THEY ARE

NOT IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES.

NEVER USE IN CANADA.

EXTENSION CORDS

The use of any extension cord will cause some loss of power. Use the

following table to determine the minimum wire size (A.W.G-American

Wire Gauge) extension cord. Use only 3-wire extension cords which

have 3-prong grounding type plugs and 3-hole receptacles which accept

the tool’s plug.

For circuits that are further away from the electrical circuit box, the wire

size must be increased proportionately in order to deliver ample voltage

to the motor. Refer to Fig.2 for wire length and size.

FIGURE 1

LENGTH OF

CONDUCTOR

0-25 FEET

26-50 FEET

51-100 FEET

WIRE SIZES REQUIRED

(AMERICAN WIRE GAUGE)

220V LINES

NO.14

NO.12

NO.10

PROPERLY GROUNDED OUTLET

CURRENT CARRYING PRONGS

GROUNDING PRONG

FIGURE 2

MAGNETIC SWITCH AND EMERGENCY STOP bUTTON

Starting and stopping the machine

The magnetic switch (A) Fig.3 which activates the cutterhead is

located on the front left side of the Jointer/Planer. To turn the

Jointer/Planer “On” press the green button (B). To stop the Plan-

er, simply press the red “EMERGENCY STOP” button (C). When

pressed, this switch is equipped with a safety feature that

ensures the machine remains “OFF” until the red stop switch is

twisted and released.

Summary of Contents for KC-12HJPC

Page 1: ...INSTRUCTION MANUAL MODEL KC 12HJPC COPYRIGHT 2017 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 12 INDUSTRIAL JOINTER PLANER WITH SPIRAL CUTTERHEAD...

Page 2: ...or accidents repairs done by an unauthorized service centre alterations and lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental spe...

Page 3: ...ol to reach them 19 CHECk DAMAGED PARTS Before further use of the tool a guard or other parts that are damaged should be carefully checked to ensure that they will operate properly and perform their i...

Page 4: ...15 4 dust chute Planer mode 16 4 dust chute release pin 17 Planing thickness scale indicator 18 Planer table raising lowering handwheel 19 Planer table lock handle 20 Planer power feed lever 21 Planer...

Page 5: ...R JOINTER PLANER DO NOT REMOVE OR ALTER THE GROUNDING PRONG IN ANY MANNER 220V OPERATION As received from the factory your Jointer Planer is ready to operate on 220V circuit This Jointer Planer is int...

Page 6: ...unting pan head screws through the two holes D in the main switch housing as shown in Fig 4 4 Reinstall the switch cover B using the 2 white plastic screws A SWITCHING FROM JOINTER MODE TO PLANER MODE...

Page 7: ...nd then locked into position It should not be adjusted further in the jointing operation 2 Using The Cutterhead Guard The cutterhead guard A Fig 9 should be properly positioned so that it rests agains...

Page 8: ...the table pitch and tilt at the back or adjusting the two cap screws that adjust the table at the front 1 Disconnect the machine from the power source 2 Loosen the table lock levers and lift the table...

Page 9: ...y turning counterclockwise Note The cutter insert and the seat should be as clean as possible This will prevent breakage of inserts and ensure proper insert alignment 3 If cutter insert is damaged rep...

Page 10: ...planer table has been set parallel to the cutterhead in the factory However table alignment should be checked to ensure there hasn t been any movement during shipment To check Planer table alignment 1...

Page 11: ...feed the workpiece with the grain when possible and avoid feeding a workpiece through against the grain Feed ing against the grain could result in chipped or uneven surfaces Jointing Jointing produce...

Page 12: ...and outfeed sides of the machine basic operation principles 1 Position the workpiece with the side to be planed facing upward toward the cutterhead 2 Turn on the planer and engage the feed rollers 3 R...

Page 13: ...clean and regularly clear the machine of sawdust and debris 3 Make sure you are wearing proper attire for operating machinery This includes safety glasses and hearing protection Avoid loose fitting c...

Reviews: