background image

INSTALLATION   INSTRUCTIONS

SAVE    THESE    INSTRUCTIONS

 OWNERS GUIDE & INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH HEATER FOR HOME OWNER

KING ELECTRICAL MFG. COMPANY • 9131 10th Ave So. • Seattle, WA 98108 •  Ph: 206.762.0400 • Fax: 206.763.7738 • www.king-electric.com

21

¾

"

13"

½

"

This  heater  includes  a  visual  alarm 
to  warn  that  parts  of  the  heater  are 
getting  excessively  hot.  If  the  alarm 
flashes  immediately  turn  the  heater 
off  and  inspect  for  any  objects  on  or 
adjacent to the heater that may cause 
high temperatures

Do not operate the 

heater with the alarm flashing.

1250 • 1500 • 1750 • 2000 • 2500 • 2750

WATTAGES AVAILABLE IN ONE UNIT

INSTALLATION INSTRUCTIONS

This heater is shipped from the factory 
wired for maximum wattage of  2750 
Watts at 120 Volts. To reduce the watt-
age unplug (disconnect) an insulated 
push on terminal and wrap with electri-
cal tape to prevent the possibility of 
electrical contact with other parts.

Feild Wattage Selection 

A - ORANGE

  Disconnects 750 Watts 

B - BLUE

       Disconnects 500 Watts

  

C - YELLOW

  Disconnects 250 Watts

D - BLACK

      

Do Not Disconnect 

 (Common)

E - RED          Do Not Disconnect

Insulated Push on 

Terminal

A

BLUE

 750 WATT

 250 WATT

RED

YELLOW

C

B

E

ORANGE

RED

E

BLACK #14 

 

END VIEW OF ELEMENT

SHOWING QUICK  CONNECT  TERMINALS

A

E

D

Common

 

750

E

E

C

D

Common

 

750

B

 

  

 500

 

 250

 

   

500

 500 WATT

 500 WATT

LIMIT

RED #14

BLACK #16

1

2

3

4

L2

BLACK

ORANGE #14

Insulated Push on 

Terminal

OFF 

....... L1-0, L2-0

FAN 

....... L1-2, L2-4

HEAT

...... L1-1, L2-4, L2-3

 750 WATT

Rotary 
Switch

L1

L1

L2

VISUAL
ALARM

D

D

LPW1227

Pic-A-Watt

Metal Sheath Element

FAN DELAY

1-3 N.C. , 1-2 N.C.
1-2 Closes on Temp Rise

LPW1227.indd : 4/08

Safety Light

BLACK#16

ORANGE#14

GRAY #16

PURPLE #16

Thermostat
Connections

FAN

2

3

1

FAN

DELAY

ORANGE#14

Reviews: