SPECIFICATIONS & 

ELECTRICAL INFORMATION

WARNING

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE COMPRESSOR DISCONNECTED FROM THE
POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

SPECIFICATIONS

Model ..............................................................................................................................................................................................8491
Voltage ............................................................................................................................................................................................120V
Amperage..........................................................................................................................................................................................12A
RPM (no load speed) ..................................................................................................................................................................17,000
Phase ....................................................................................................................................................................................................1
Hertz................................................................................................................................................................................................60Hz
Maximum operating pressure ....................................................................................................................................................150 PSI
CFM @ 40 PSI ................................................................................................................................................................................3.40
CFM @ 90 PSI ................................................................................................................................................................................2.50
Tank size ....................................................................................................................................................................................6 Gallon

POWER SUPPLY

WARNING:

YOUR MACHINE MUST BE CONNECTED TO A 110-

120V, 15-AMP CIRCUIT BREAKER. FAILURE TO CONNECT IN
THIS WAY CAN RESULT IN INJURY FROM SHOCK OR FIRE.

GROUNDING

This machine must be grounded. If it should malfunction or break-
down, grounding provides a path of least resistance for electric
current, to reduce the risk of electric shock. This machine is equipped
with a cord having an equipment-grounding conductor and grounding
plug. The plug must be plugged into an appropriate outlet that is prop-
erly installed and grounded in accordance with all local codes and
ordinances.

Your machine must be properly grounded. Not all outlets are
properly grounded. If you are not sure if your outlet is properly
grounded, have it checked by a qualified electrician.

WARNING: 

TO MAINTAIN PROPER GROUNDING, DO NOT

REMOVE OR ALTER THE GROUNDING PRONG IN ANY MANNER.

WARNING:

IF NOT PROPERLY GROUNDED, THIS MACHINE CAN

CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN
DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER
CORD IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED
IMMEDIATELY.

110-120V OPERATION

As received from the factory, your machine is ready to run for 110-
120V operation. This machine is intended for use on a circuit that has
an outlet and a plug which looks like the one illustrated in Fig.1.

WARNING:

DO NOT USE A TWO-PRONG ADAPTOR FOR THEY

ARE NOT IN  ACCORDANCE WITH LOCAL CODES  AND
ORDINANCES. NEVER USE IN CANADA.

EXTENSION CORDS

The use of any extension cord will cause some loss of power. Use the
following table to determine the minimum wire size (A.W.G-American
Wire Gauge) extension cord. Use only 3-wire extension cords which
have 3-prong grounding type plugs and 3-hole receptacles which
accept the tool’s plug.

For circuits that are further away from the electrical circuit box, the wire
size must be increased proportionately in order to deliver ample
voltage to the motor. Refer to Fig.2 for wire length and size.

FIGURE 1

120V GROUNDED OUTLET

GROUNDING 
PLUG

CURRANT 
CARRYING
PRONGS

FIGURE 2

Tool’s

Amperage

Rating

3-6
6-8

8-10

10-12
12-16

Cord Size in A.W.G.

Cord Length in Feet

25

50

100 150

18

16

16

14

18

16

14

12

18

16

14

12

18

16

14

12

14

12

-

-

Summary of Contents for 8491

Page 1: ...KING CANADA INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL 8491 6 GALLON 150 PSI OIL FREE AIR COMPRESSOR plus plus performance performance ...

Page 2: ...dents repairs done by an unauthorized service center alterations and lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take advantage of this limited warranty return the product at your expense together with your dated proof of purshase to an authorized Kin...

Page 3: ...10 USE RIGHT TOOL Don t force the tool or the attachment to do a job for which it was not designed 11 WEAR PROPER APPAREL Do not wear loose clothing gloves neckties or jewelry rings watch because they could get caught in moving parts Non slip footwear is recommended Wear protective hair covering to contain long hair Roll up long sleeves above the elbows 12 ALWAYS WEAR SAFETY GLASSES Always wear sa...

Page 4: ...HAT CAN HAPPEN 1 Failure to properly drain condensed water from the tank causing rust and thinning of the steel tank 2 Modifications or attempted repairs to the tank 3 Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure 4 Excessive vibration can weaken the air tank and cause rupture or explosion Attachments Accessories Exceeding the ope...

Page 5: ...d by a qualified electrician WARNING TO MAINTAIN PROPER GROUNDING DO NOT REMOVE OR ALTER THE GROUNDING PRONG IN ANY MANNER WARNING IF NOT PROPERLY GROUNDED THIS MACHINE CAN CAUSE ELECTRICAL SHOCK PARTICULARLY WHEN USED IN DAMP LOCATIONS TO AVOID SHOCK OR FIRE IF THE POWER CORD IS WORN OR DAMAGED IN ANY WAY HAVE IT REPLACED IMMEDIATELY 110 120V OPERATION As received from the factory your machine is...

Page 6: ...each particular accessory the outlet regulated air pressure may have to be adjusted while operating the accessory OUTLET PRESSURE GAUGE C FIG 3 The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator The pressure is controlled by the regulator and is always less than or equal to the tank pressure TWO QUICK CONNECT COUPLERS E FIG 3 Connect one or two air h...

Page 7: ... air leaks it is recommended to install Teflon Tape not supplied on the threads at both ends of the your hose WARNING Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating of the tool being used 3 Turn the switch to the On position and allow...

Page 8: ...ith Teflon tape Drain tank through drain valve Move compressor to area of less humidity Risk of electric shock TROUBLE SHOOTING MAINTENANCE Before doing any maintenance or adjustments to your air compressor the following safety precautions should be taken Disconnect power cord from power source Release air tank pressure Daily or before each use 1 Drain condensation from tank 2 Check for any unusua...

Reviews: