ELECTRICAL INFORMATION &
SPECIFICATIONS
Model ..........................................................................................................................................................................................8324NS
Voltage ..................................................................................................................................................................................110V-120V
Input power ................................................................................................................................................................................15 Amp.
No load speed ......................................................................................................................................................................4,800 RPM
Blade size..........................................................................................................................................................................10” x 80 teeth
Arbor size ..........................................................................................................................................................................................5/8”
Miter table angles............................................................................................................................0
0
, 15
0
, 22.5
0
, 30
0
, 45
0
left and right
Crosscut 90
0
....................................................................................................................................................................2-3/4” x 5-7/8”
Miter 45
0
..........................................................................................................................................................................2-3/4” x 4-5/16”
Bevel 45
0
..........................................................................................................................................................................1-1/2” x 5-7/8”
Compound (Miter & Bevel 45
0
) ......................................................................................................................................1-1/2” x 4-5/16”
WARNING
: The warnings, cautions, and instructions discussed in this
instruction manual can’t cover all possible conditions and situations
that may occur. It must be understood by the operator that common
sense and caution are factors which cannot be built into this product,
but must be supplied by the operator.
POWER SUPPLY
WARNING:
YOUR MITER SAW MUST BE CONNECTED TO A 110V-
120V, 15-AMP CIRCUIT BREAKER. FAILURE TO CONNECT IN THIS
WAY CAN RESULT IN INJURY FROM SHOCK OR FIRE.
110V-120V OPERATION
As received from the factory, your Miter Saw is ready to run for 110V-
120V operation. This Miter Saw is intended for use on a circuit that has
an outlet and a plug which looks like the one illustrated in Fig.1.
DOUBLE INSULATION
Double insulated tools are equipped with a polarized two-prong plug
(one blade is wider than the other). This plug will fit in a polarized outlet
only one way. If the plug does not fit fully into the outlet, reverse the
plug. If it still does not fit, contact a qualified electrician to install a
polarized outlet. Do not alter or change the plug in any way. Double
insulation eliminates the need for three wire grounded power supply
and grounded power cords.
EXTENSION CORDS
The use of any extension cord will cause some loss of power. Use the
chart in Fig.2 to determine the minimum wire size (A.W.G-American
Wire Gauge) extension cord. Use only 3-wire extension cords which
have 3-prong grounding type plugs and 3-hole receptacles which
accept the tool’s plug.
For circuits that are further away from the electrical circuit box, the wire
size must be increased proportionately in order to deliver ample voltage
to the Miter Saw motor. Refer to Fig.2 for wire length and size.
SPECIFICATIONS
WARNING!
ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE MACHINE DISCONNECTED FROM THE
POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!
FIGURE 1
FIGURE 2
Tool’s
Amperage
Rating
3-6
6-8
8-10
10-12
12-16
Cord Size in A.W.G.
Cord Length in Feet
25 50 100 150
18
16
16
14
18
16
14
12
18
16
14
12
18
16
14
12
14
12
-
-
POLARIZED
OUTLET
POLARIZED
2-PRONG PLUG