Technical Information

Note: Not intended to be sterilized.

Not for use in an OXYGEN RICH ENVIRONMENT

Modes

Typical operation

time of Battery

Behaviour of equipment

while the rechargeable

internal electrical power

source is charging:

Typical service

life of Battery

Output intensity

Output Voltage

Pulse duration

Power supply

Powered by internal 3.7V li-ion battery

Biphasic rectangular wave pulse

100us (Microseconds)

1-100Hz (Hz=vibration per second)

Max. 70Vpp ±20%(at 500ohm load)

10 min, 20 min, 30 min, 40 min,

50 min, 60 min

No use (in storage): 1 year

In use: 30 uses

0 to 20 levels, adjustable

12 auto modes

To use both channels together at level 10,

the battery can be used 570 mins after fully

charged. If to use at level 20, the battery can

be used for 180 mins after fully charged.

The battery icon on the right corner will flash

during charging and will be still with full

capacity after fully charged.

300 times of recharging

Automatic shutoff

Degree of protection against electric shock

Type of protection against electric shock

Grade of waterproof

Product life

Lifetime for electrode pad

Mode of operation

Software version

The time required for equipment to warm from

the minimum storage temperature between

uses until it is ready for intended use

The time required for me equipment to cool

from the maximum storage temperature

between uses until it is ready for intended use

Adapter for charging

After 20 minutes without use

Type BF applied part

Internally powered equipment

IP22

1 year

Continuous operation

A0

30 minutes

15 minutes

Please use output DC5V

and output current 0.3-2.0A

adapter for charging

Treatment time

Pulse frequency

Waveform and wave shape

Model/type

TD3

Weight

40g

12

For support… Visit our website: www.kinetikwellbeing.com / Email: [email protected] / Call: +44 1483 937969

Summary of Contents for TD3 Series

Page 1: ...TD3 Series...

Page 2: ...Specifications Parts Setup How to Use Recommended Use Positions Cleaning and Maintenance Technical Information Troubleshooting Environmental Condition for Transport and Storage Symbols interpretation...

Page 3: ...help Our Customer Care team are available from 9am 5pm Monday to Friday excluding bank holidays We promise to respond to all queries and will ensure to resolve any issue you may be having You can rea...

Page 4: ...ormal household and work activities Safety Warning Contraindications Do not use this device on patients who have a cardiac pacemaker implanted defibrillator or other implanted metallic or electronic d...

Page 5: ...ndition requiring the active supervision of a physician Precautions Do not use this device while driving Do not use this device while sleeping Do not use this device in high humidity areas such as a b...

Page 6: ...llowing 1 To consult with your physician before using this device The stimulation from the device may i cause lethal rhythm disturbances to the heart in susceptible individuals ii disrupt the healing...

Page 7: ...ry containing device according to the local state or federal laws The long term effects of electrical stimulation are unknown Since the effects of stimulation of the brain are unknown stimulation shou...

Page 8: ...the eyes and to the head and face Patients should stop using the device and should consult with their physicians if they experience adverse reactions from the device Accessories included in the packag...

Page 9: ...desired ON OFF USB port Battery Indicator LCD Display Countdown Timer Intensity Indicator Decrease Intensity Mode Selection B Channel Timer A Channel Output A channel Output B channel Pause Play a lo...

Page 10: ...button to decrease the intensity press the button When pressing the button the device will pause treatment this will be indicated by a lock symbol on the screen When pressing T one of the six time opt...

Page 11: ...30 40 50 60 10 20 30 40 50 60 10 20 30 40 50 60 10 20 30 40 50 60 10 20 30 40 50 60 10 20 30 40 50 60 10 20 30 40 50 60 10 20 30 40 50 60 10 20 30 40 50 60 10 20 30 40 50 60 Frequency Hz 68 9 12 5 55...

Page 12: ...ipe again The electrode pads that come with the device are disposable and should be replaced after they lose their adhesiveness please contact Kinetik Wellbeing for replacements We recommend that user...

Page 13: ...t corner will flash during charging and will be still with full capacity after fully charged 300 times of recharging Automatic shutoff Degree of protection against electric shock Type of protection ag...

Page 14: ...h adhesive surface of pads gently with your fingertips for about 3 seconds under slow running water Reduce the application time or reduce the intensity Replace electrode pad The therapy time is too lo...

Page 15: ...ndor for replacements Replace the pad Were the pads stored under high temperature high humidity or direct sunshine Charge the battery The cord is broken Replace the cord Have you removed the transpare...

Page 16: ...t Keep the product in the dry place Away from water and rain This way up Product package should be recycled Unrecyclable Date of manufacture Serial number Read the instructions actual symbol colours a...

Page 17: ...cal devices Symbols to be used with medical device labels labelling and information to be supplied Part 1 General requirements EN 1041 Information supplied by the manufacturer with medical devices IEC...

Page 18: ...o or stacked with other equipment and that if adjacent or stacked use is necessary this machine should be observed to verify normal operation in the configuration in which it will be used EMC and FCC...

Page 19: ...tic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Emission test Compliance Electromagnetic environment g...

Page 20: ...pply lines 1 kV for input output lines 2kV for power supply lines Mains power quality should be that of a typical commercial or hospital environment 1 kV line s to line s 2 kV line s to earth 1 kV dif...

Page 21: ...tion during power mains interruptions it is recommended that the device be powered from an uninterruptible power supply or a battery 3 A m 3 A m Power frequency magnetic fields should be at levels cha...

Page 22: ...uipment should be used no closer to any part of the device including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recomme...

Page 23: ...utput power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determ...

Page 24: ...ic site survey should be considered If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above the device should be observed to verify...

Page 25: ...on and reflection from structures objects and people For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equa...

Page 26: ...cause harmful interference to radio or television reception which can be determined by turning the product on or off the user is encouraged to try to correct the interference by one or more of the fol...

Page 27: ...Service LLC Repr sentanzb ro Heerdter Lohweg 83 40549 D sseldorf Harvard Medical Devices Ltd HK Unit 1002 10th Floor Railway Plaza 39 Chatham Road South Tsimshatsui Kowloon Hong Kong 26 For support V...

Reviews: