background image

Kinetik Labs
KLIR-RM1KIT

Recess Mount IR Kit

Kinetik Labs
KLIR-RM1KIT

Recess Mount IR Kit

Recess Mount IR Kit

Instruction Manual

Introduction

Contents

Safety Instructions

Description

Advanced Installation

Troubleshooting

Component Dimensions

Specifications

Limited Warranty

Installation Instructions

Multi Zone System Wiring Diagram 

(requires additional receivers)

Box Contents

Thank you for purchasing this Kinetik Labs Infra Red distribution kit. Please 
read  these  instructions  carefully  to  complete  your  installation  quickly  and 
efficiently for trouble free installation.  

Section

Introduction

Safety Instructions

Description

Box Contents

Installation Instructions

Single Zone System Wiring Diagram

Multi Zone System Wiring Diagram

Advanced Installation

Troubleshooting

Component Dimensions

Specifications

Limited Warranty

Page

3

3

3

4

5

6

6

7

8

9

10

11

Keep  this  product  away  from  small  children  and  animals  as  it 
contains small parts.

Keep  this  product  away  from  naked  flames  and  sources  of 
ignition.

Warning:

 Although the voltages used are very low in the system 

care should be taken not to touch bare wires as they may be live.

Warning: 

Do not expose this product to liquids as this may cause 

fire or electrical shock. 

Caution:

 Installation should be carried out and checked before 

providing power to the system.  Damage caused  by improper 
wiring is not covered by the warranty. 

!

The KLIR-RM1KIT is an Infra Red (IR) signal transport device.  It is designed 
to extend the communication between an IR remote control and respective AV 
equipment  e.g.  Blu-ray  player,  set-top  box,  amplifier  etc,  which  can  be  in  a 
different  room  or  hidden  location.    The  IR  receiver  has  a  recess  mount  for 
discreet installation in walls, ceilings or cupboard doors.

Drill a hole 13mm wide where you wish to position the IR receiver.  
Remove the nut,  push the receiver cable and thread through the hole 
with the lens facing into the room.  Screw the nut back on until tight to 
hold the receiver in place.

Please note:  For full installation details please also read the ‘Advanced 
Installation’ and ‘Troubleshooting’ sections.  

Please note:  This process is likely to require two people 

It is possible to connect 
and power up to 3 IR 
receivers simultaneously

See ‘Receiver wired 
connection’ diagram
in the ‘Advanced 
Installation’ section

No operation. 

Symptom

Check

Problem / Solution

The connection block 
power LED is off.  

Connection block is not 
receiving power. Check
mains supply is on.

No operation.  
IR receiver LED 
constantly red.

Block ambient light to 
the sensor to see if light
goes out.  If it does...

The receiver is being
exposed to excess light.  
Install away from light 
sources.

No operation.  
Emitter lights not 
responding.

Check wiring and power

Correct wiring / power

No operation.  System 
LEDs responding.

Location of emitters
on front of AV 
equipment.

Equipment might be
receiving excess IR.
Correct placement should
solve this.

No operation.  
IR receiver LED 
constantly red.

Block ambient light to 
the sensor to see if light
stays on.  If it does...

It’s likely to be a wiring 
fault.  

(See ‘Receiver 

wired connection’ section)

No operation.  
Connection block LED is 
on.

System is receiving
incorrect power.  Try 
another power supply.

1.

Clean the source equipment surfaces over the IR pick ups, remove 
the backing from the emitter heads and stick them over each IR pick 
up. 

3.

4.

Attach the correct UK / Europe plug adaptor onto the power adaptor. 
Connect  the  adaptor  to  the  connection  block  input  labelled  ‘Power 
12V DC’ and plug it into the mains.  Now switch on the mains supply.  

The red LED power indicator should now be lit and the emitters and receiver 
will flash when passing an IR signal to show the system is working.  Once you 
are happy the system is working correctly stick the supplied emitter covers over 
the emitters.

5.

Plug the emitter jacks into any of the connection block outputs marked 
‘Emitters 1,2,3 or 4’.

Plug  the  IR  receiver  jack  securely  into  the  connection  block  input 
indicated ‘IR Receiver’.

2.

Cable extension 

The  IR  receiver  and  emitter  cables  can  be  extended  to  custom  lengths  if 

required.  It is recommended that two strands of CAT5 are used per signal.

To  do  this,  firstly  you  need  to  determine  the  length  of  the  run  and  cut  that 

amount.  Now cut the receiver / emitter cable and use the CAT5 to extend the 

cable length. 

You  must  ensure  you  connect  the  identical  cores  as  this  may  potentially 

damage the components and the system will not work. 

It is not necessary to use the receiver’s jack termination when you have cut the 

cable.  You can instead use the connection block’s black Phoenix connector.

Finding IR pickups

You may occasionally come across equipment without a visible IR pick up.  

If this is the case, set up the system as described in the main instructions but 

do not stick the emitter on that unit.  Turn the IR kit on and fire a remote control 

button (of a code you’ll see the unit respond to e.g. power on / off etc.) repeat-

edly at the IR receiver, but not allowing the remote control line of sight of the 

source  equipment.    While  doing  this  the  emitter  should  be  guided  over  the 

front of the equipment until it responds to the relevant code.  Once this is found 

the emitter should be attached there.

CD P

layer

Mod

el nu

mbe

r

Amp

lifier

Mod

el nu

mbe

r

Receiver (IR jack in)

AV equipment cupboard / room

Blu-ray Player

Amplifier

Power supply

Connection block

Zone 1 (Lounge)

IR Receiver

Zone 2 (Bedroom)

Zone 3 (Kitchen)

Receiver wired connection

Solid line 
Black
Striped

12V DC
Ground
IR


:
:

Single Zone System Wiring Diagram

CD P

layer

Mod

el nu

mbe

r

Amp

lifier

Mod

el nu

mbe

r

Receiver (IR jack in)

AV equipment cupboard / room

Blu-ray Player

Amplifier

Power supply

Connection block

Zone 1 (Lounge)

IR Receiver

General

Model Number: 

 

 

KLIR-RM1KIT

Components: 

 

 

1x KLIR-RMR1 recess mount IR receiver

 

 

 

 

1x KLIR-CB1 connection block

 

 

 

 

2x KLIR-IRE2 dual visible IR emitters

 

 

 

 

2x MONO JACK 3.5mm jack to jack cables

 

 

 

 

4x KLIR-EC emitter covers

Additional accessories: 

 

2x bezels for KLIR-RMR1 IR receiver

 

 

 

 

4x replacement emitter sticky tabs

 

 

 

 

4x replacement emitter cover adhesive tabs

 

 

 

 

1x instruction manual

IR frequency bandwidth:   

 

38kHz +/- 2kHz

Control range:  

 

 

15m (6m in direct sunlight)

Reception angle:    

 

+/- 45 degrees 

Connectivity

Connection block inputs: 

 

1x 12V DC 

 

 

 

 

1x 3.5mm jack IR

 

 

 

 

1x Phoenix connector (12V DC / Ground / IR)

Connection block outputs: 

 

4x 3.5mm jack IR

Expandability 

Max. number of IR emitters:    

8 (4x dual emitters)

Max. number of IR receivers:    

3

Max. cable distance - receiver to block:  300m
Max. cable distance - block to emitter:  10m

Mechanical

Power (supplied adapter): 

 

12V DC, 660mA

Power consumption (stand by): 

13mA

Power consumption (in use):   

40mA (approximate)*

Weight:   

 

 

650g

Dimensions

KLIR-RMR1 (HxWxD): 

 

14.8 x 14.8 x 51 mm (cable length 2m) 

KLIR-CB1 (HxWxD):  

 

23 x 70.5 x 55.5 mm

KLIR-IRE2 (HxWxD): 

 

7 x 10 x 14 mm (x2) (cable length 3m)

KLIR-PS1 (HxWxD): 

 

57 x 49 x 64 mm (with UK plug)

 

 

 

 

57 x 45 x 77.5 mm (with EU plug)

*Power consumption can vary with system size, combined IR equipment and signal variations.

This Kinetik Labs product is warranted free of defects in workmanship and materials on purchase.  
If the goods are found to be defective within the warranty period, they will be repaired or replaced, 
at AWE Europe Ltd’s option, without charge, on a parts and labour only basis, upon satisfactory 
proof of purchase from the vendor and date of purchase.  This warranty does not apply if, in the 
judgement of AWE Europe Ltd, the product fails due to damage from shipment, handling, storage, 
accident, abuse, or misuse, or if it has been used or maintained in a manner not conforming to 
product manual instructions, has been modified in any way, or has had any serial number removed 
or  defaced.    Repair  by  anyone  other  than  AWE  Europe  Ltd  or  an  approved  agent  will  void  this 
warranty.  The maximum liability of AWE Europe Ltd under this warranty is limited to the purchase 
price of the product covered by the warranty.  AWE Europe Ltd shall not under any circumstances 
be  liable  to  any  person  for  any  special,  incidental,  indirect  or  consequential  damages,  including 
without  limitation,  damages  resulting  from  use  or  malfunction  of  the  products,  loss  of  profits  or 
revenues or costs of replacement goods, even if AWE Europe Ltd is informed in advance of the 
possibility of such damages. 
 
In the first instance consumers should contact their vendor.  
Territorial distributor details can be found at www.kinetiklabs.com

Strange / partial 
operation of equipment

Equipment pick ups may
be receiving mixed 
signals, often occurring 
from reflective surfaces.

Put on IR emitter covers
supplied.

Connect all components
and power system.  Meter 
from Phoenix connector
‘V+’ and ‘G’ to check it’s 
a steady 12V.  Always 
meter ‘under load’.

Emitters

V+ G IR

IR

Receiver

Power

DC 12V

1

2

3

4

57mm

49mm

45mm

12mm

5mm

14mm

14mm

3.5mm

77.5mm

64mm

Cable length: 1500mm (1.5m)

Full length: 3000mm (3m)

Split length: 900mm (0.9m)

KLIR-PS1 Power Supply

KLIR-IRE2 Dual Visible Emitters

SIDE

UK UNDERSIDE

END

TOP

EUROPE UNDERSIDE

70.5mm

23mm

46.5mm

55.5mm

KLIR-CB1 Connection Block

SIDE

TOP

Emitters

V+ G IR

IR

Receiver

Power

DC 12V

1

2

3

4

51mm

14mm

3.5mm

IR

G

V+

Cable length: 2000mm (2m)

KLIR-RMR1 Recess Mount Receiver

SIDE

END

WIRING

10mm

7mm

x2

x2

x4

x1

x1

x1

x1

x2

x4

x4

KLIR-RMR1

MONO JACK

KLIR-IRE2

KLIR-PS1

 UK/Europe power supply

KLIR-CB1

KLIR-EC

Emitter covers

Mono jack to jack cable

Replacement emitter adhesive tabs

 Bezels for KLIR-RMR1 IR receiver

Replacement pads for emitter covers

Recess mount receiver

Dual visible IR emitter

Instruction manual for KLIR-RM1KIT

 IR connection block

Emitters

/Jacks

Emitters

/Jacks

3

4

5

6

7

8

9

10

11

www.kinetiklabs.com

© Copyright AWE Europe Ltd 2010. All rights reserved.  Design and specifications are subject to change without prior 
notice.  No part of this document may be reproduced, for any purpose, without prior written permission from AWE 
Europe Ltd. AWE Europe Ltd is not liable for omissions or for technical or editorial errors herein or for damages directly 
or indirectly resulting from the use of this Kinetik Labs product.  ‘Kinetik Labs’ and the ‘Kinetik’ logo are trademarks of 
AWE Europe Ltd.  

Kinetik Labs

KLIR-RM1KIT

Recess Mount IR Kit

Instruction

 Manual

Emitters

V+ G IR

IR

Rece

iver

Pow

er

DC 1

2V

1

2

3

4

Kinetik

 Labs

KLIR-RM1KIT

47mm

12mm

14.8mm

14.8mm

Summary of Contents for KLIR-RM1KIT

Page 1: ...Recess Mount IR Kit Instruction Manual Emitters V G I R I R R e c e i v e r P o w e r D C 1 2 V 1 2 3 4 Kinetik Labs KLIR RM1KIT...

Page 2: ...duction Safety Instructions Description Box Contents Installation Instructions Single Zone System Wiring Diagram Multi Zone System Wiring Diagram Advanced Installation Troubleshooting Component Dimens...

Page 3: ...in the system care should be taken not to touch bare wires as they may be live Warning Do not expose this product to liquids as this may cause fire or electrical shock Caution Installation should be...

Page 4: ...Replacement emitter adhesive tabs Bezels for KLIR RMR1 IR receiver Replacement pads for emitter covers Recess mount receiver Dual visible IR emitter Instruction manual for KLIR RM1KIT IR connection bl...

Page 5: ...ds and stick them over each IR pick up 3 4 Attach the correct UK Europe plug adaptor onto the power adaptor Connect the adaptor to the connection block input labelled Power 12V DC and plug it into the...

Page 6: ...r IR jack in AV equipment cupboard room Blu ray Player Amplifier Power supply Connection block Zone 1 Lounge IR Receiver Zone 2 Bedroom Zone 3 Kitchen Single Zone System Wiring Diagram CD Playe r Mode...

Page 7: ...ssary to use the receiver s jack termination when you have cut the cable You can instead use the connection block s black Phoenix connector Finding IR pickups You may occasionally come across equipmen...

Page 8: ...emitters on front of AV equipment Equipment might be receiving excess IR Correct placement should solve this No operation IR receiver LED constantly red Block ambient light to the sensor to see if li...

Page 9: ...9m KLIR PS1 Power Supply KLIR IRE2 Dual Visible Emitters SIDE UK UNDERSIDE END TOP EUROPE UNDERSIDE 70 5mm 23mm 46 5mm 55 5mm KLIR CB1 Connection Block SIDE TOP Emitters V G IR IR Receiver Power DC 1...

Page 10: ...1x 12V DC 1x 3 5mm jack IR 1x Phoenix connector 12V DC Ground IR Connection block outputs 4x 3 5mm jack IR Expandability Max number of IR emitters 8 4x dual emitters Max number of IR receivers 3 Max...

Page 11: ...nstructions has been modified in any way or has had any serial number removed or defaced Repair by anyone other than AWE Europe Ltd or an approved agent will void this warranty The maximum liability o...

Page 12: ...of this document may be reproduced for any purpose without prior written permission from AWE Europe Ltd AWE Europe Ltd is not liable for omissions or for technical or editorial errors herein or for da...