STEP #4 Install SANI Cartridge(s)

 

a.

 Generously apply lubricant to all three O-rings and install  

  SANI cartridge(s) into the filter manifold by aligning the  
  tabs on the filter with the notches on the manifold 

 and  

  push upward to insert filter. 

CAUTION: Filter may be heavy.

 

For KPMF/SMF filters:

 Turn cartridge clockwise (as viewed  

  from bottom), until a definite stop is felt and filter is seated. 
 

For HPF filters: 

Turn the cartridge counterclockwise (as viewed  

  from bottom), until a definite stop is felt and filter is seated.

STEP #5 System Flush

a. 

Slowly open inlet valve on manifold. 

b.

 Open downstream water lines and taps one at a time.

  Keep ONE tap open until you smell or detect sanitizing/ 
  descaling agent then close the tap.

c.

 Repeat step 5b for all downstream lines/taps, one at a time.

NOTE: IF you open a filtered water line and DO NOT detect
sanitizing/descaling agent return to step 3 and add additional
agent to cartridge(s) per your instructions.

STEP #6 System Flush Completion

a.

 After time specified for your sanitizing/descaling agent,  

  open all the filtered taps you introduced the sanitizing/descaling  
  agent into and flush for at least 5 minutes. Once complete,  
  close all taps.

b.

 Shut off inlet valve to manifold and depressurize filtration  

  system prior to removing the SANI cartridge(s)  
  (reference step 1). 

NOTE: The SANI cartridge(s) should be drained and thoroughly rinsed prior to storage or disposal.

STEP 7: Install NEW Water Filters

a.

 Remove and discard sanitary cap from top of new filter. Generously lubricate O-ring.

b. 

Align tabs on filter with notches in manifold. 

 Push upward to insert filter. 

For KPMF/SMF filters:

 Turn filter clockwise (as viewed from bottom), until a definite stop is felt and  

filter is seated.

For HPF filters:

 Turn filter counterclockwise (as viewed from bottom), until a definite stop is felt and  

filter is seated.

c. 

Slowly open inlet valve on manifold. Open the flush valve(s) and flush system for 5 minutes.  

  Close the flush valve(s). Now your water filtration system is ready for use.

Change out filter annually or when capacity has been reached.