Kinesys LibraCELL User'S Product Manual Download Page 10

10

LibraCELL

© 2017 Kinesys Projects Ltd

9

Contact Information

If you would like to get in touch with Kinesys then please use any of the following methods.

Email:

[email protected]

Website:

www.kinesys.co.uk

Tel:

+44 (0) 20 8481 9850

Fax:

+44 (0) 20 8487 0396

Mail:

Unit 2 Kempton Gate Business Centre
Oldfield Road
HAMPTON
Middlesex
TW12 2AF
United Kingdom

If our new postcode TW12 2AF is not recognised by your
mapping and satellite navigation systems - enter TW12 2HT to
find us

Google Map Link:

http://www.google.co.uk/maps?q=tw122af

Feedback

We are always keen to hear  feedback from the  users  of  Kinesys  products.  If  you have  a
feature  request  for  the  software,  any  comments  about  the  documentation or  just  want  to
say hello, please get in touch.
In the unlikely event that LibraVIEW has not performed to the high standards that we work
to and our users expect then please let us know as soon as possible.

To leave  feedback please  email  

[email protected]

 or  call  us  on  +44  (0)20  8481

9850.

If you require technical support relating to LibraCELL please contact  us  either  at  +44  (0)
20 8481 9850 or 

[email protected]

Summary of Contents for LibraCELL

Page 1: ... 2017 Kinesys Projects Ltd LibraCELL Manual Version 1 6 5 Product Manual ...

Page 2: ...rademarks While every precaution has been taken in the preparation of this document the publisher and the author assume no responsibility for errors or omissions or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it In no event shall the publisher and the author be liable for any loss of profit or any other...

Page 3: ...ntents Part 1 Introduction 4 Part 2 Power On 4 Part 3 Factory Defaults 5 Part 4 The Default Display 5 Part 5 Operation 5 Part 6 Editing A Parameter Via The Keypad 7 Part 7 Connections 8 Part 8 Adjusting The Zero Offset 9 Part 9 Contact Information 10 ...

Page 4: ...aintains a safety factor of 5 1 up to the full rated load The3 25T 5 8 and 4 75T 3 4 versions allow 10 1 safety factors to be applied while still allowing sufficient capacities to rig one and two tonne points respectively The LibraCELL technology has the ability to resolve down to 1kg 2 2lbs Due to limitations in the manufacture of the Crosby shackle bow Kinesys specify an accuracy of 2 of the cur...

Page 5: ...ad in lbs Whilst in imperial mode values entered for Tare MIN and MAX will be in lbs If the displayed load is above the maximum trip value the display will flash alternately between the load and the message MAX If the displayed load is below the minimum trip value the display will flash alternatively between the current load and the message MIN Whilst in the default display mode and if no trips ar...

Page 6: ...gether can result in the LibraCELL producing less accurate readings 2 The Crosby and Kinesys logos should be on the same side of the LibraCELL LibraCELLs that feature a 5 digit unique identifier tag will be on the inside of the bow A LibraCELL with the bow fitted correctly A LibraCELL with the bow fitted incorrectly 3 The nut that holds the bow and load pin together should always be fully tightene...

Page 7: ... to revert to the normal display mode Parameter edit mode When the desired parameter is selected pressing the M button will cause the display to enter the parameter edit mode If the currently selected parameter cannot be changed the display will show for as long as the M button is pressed If the currently selected parameter can be edited the display will show its value and the up and down buttons ...

Page 8: ...rial lbs kg Max Yes Set the load over which the display will flash tmax 0 No Trip Min Yes Set the load under which the display will flash tmin 0 No Trip Disp Yes Set the display YES or NO YES Log No Display the maximum load read by the cell since the log was last reset 0 Rate No Rating of the cell maximum load Date No Calibration Date MMYY Ver No Display the version of the firmware in the cell 7 C...

Page 9: ... cells use a scaling factor of 3611 For 4 75T cells use a scaling factor of 5278 8 Adjusting The Zero Offset All LibraCELLs are calibrated when they leave the factory during the lifetime of the cell the zero point of the LibraCELL can drift slightly resulting in reduced accuracy This is often seen as the LibraCELL registering a weight when load applied If this occurs the end user has the option to...

Page 10: ...12 2HT to find us Google Map Link http www google co uk maps q tw122af Feedback We are always keen to hear feedback from the users of Kinesys products If you have a feature request for the software any comments about the documentation or just want to say hello please get in touch In the unlikely event that LibraVIEW has not performed to the high standards that we work to and our users expect then ...