Remove the 2 screws holding the left hand board bracket. Remove the 
bracket and left hand lining board. 

Remove the screw holding the pilot draught shield to the pilot bracket and 
lift the shield away. 

Remove the six screws securing the control mount platform to the firebox. 
Take care not to damage the gasket. 

Replace the control mount platform (if it has been removed) and secure with the 
six screws previously removed. Replace the pilot shield and the lining board and 
bracket. Re-connect the gas supply. Place the burner and air guide assembly in 
position  ensuring  that  the  mixing  tube  locates  in  its  hole  in  the  burner  mount 
over the injector and fix in place with the four screws removed in paragraph 5. 
Replace the refractory shapes that were in place on the burner. 

10 

Replace the black ceramic granules in the tray attached to the air guide. Replace 
the ‘Cotswold Stones’ exactly as they were removed making sure that the centre 
row are replaced on the spikes using the original piecing in the stones. 

11 

After cleaning the glass door inside and out replace it and secure with the eight 
nuts. Tighten the nuts evenly. Stubborn marks can be removed with steel wool 
and detergent. 

 

AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS JOINTS. 

12 

Replace the fascia panel. 

13 

The service record sheet enclosed with these instructions should be complete to 
maintain the validity of the warranty.

  

 

Battery Replacement 

14 

HANDSET; The handset is powered by one Alkaline 9volt PP3 size battery.  If the 
fire  fails  to  respond  to  the  handset  control  check  that  the  red  LED  on  the 
handset  lights  whilst  pressing  either  of  the  two  buttons.    If  the  LED  does  not 
light, the battery in the handset requires renewing. To change the battery in the 
handset,  remove  the  battery  cover  on  the  underside  of  the  handset,  unclip  the 
battery  from  its  connector  and  put  a  new  one  put  in  its  place.    Replace  the 
cover. 

15 

BURNER;  Open  the  fascia  panel.  Lift  out  the  gas  control  battery  pack  –  signal 
receiver from its position on the bottom tray of the convector box. Slide back the 
battery  compartment  cover  and  replace  the  four  AA  size  alkaline  batteries 
observing the correct  polarities.  Replace  the  cover and then  replace the battery 
box in its clip.  

 

Summary of Contents for KBFP00RN

Page 1: ...Heater MODEL NUMBER KBFP00RN INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER This appliance is suitable for use on Natural Gas G20 at a supply pressure of 20...

Page 2: ...s is not a Do it yourself product and it must be installed by a competent person 2 The Installation Instructions must be adhered to without exception 3 The heat from this appliance will cause the wall...

Page 3: ...a Panel b Decorative trim and 4 magnets if ordered Inset Installations only a Wall plate must be used for Inset Installations APPLIANCE DATA KBFP00RN GAS TYPE NATURAL GAS SUPPLY PRESSURE 20 mbar HEAT...

Page 4: ...r the inset installation 3 Flue Terminal Position The minimum distances permissible from the flue terminal to obstructions and ventilation openings are shown below DIMENSION TERMINAL POSITION MINIMUM...

Page 5: ...gh the whole base of the builders opening fireplace recess or beneath the flue box b Project at least 275mm in front of the glass window panel c Project at least 150mm beyond each side of the edge of...

Page 6: ...s with the approval of the designers of the dwelling Fitting This appliance can be installed either by being fixed directly on to the surface or it can be inset into the inner leaf of a cavity wall Be...

Page 7: ...flue connection on the back of the heat exchanger Note that the two flue tubes are not concentric and that the inner tube is positioned towards the top of the outer tube Using a 3 5mm diameter drill...

Page 8: ...inner holes as shown in Figure 4 4 Temporally screw the convector box to the inner wall plate with four M5 screws Place the convector box over the protruding flue pipe and push the box into the hole...

Page 9: ...ox flange Fix the heat exchanger through the convector box flanges to the inner fascia using the M5 bolts supplied Replace the self tapping screws that secure the flue to the wall plate Seal the flue...

Page 10: ...panel slides up and down freely and locks in the top position COMMISSIONING 1 Before attempting to light the appliance the gas supply must be turned on by removing the cap from the isolator fitting a...

Page 11: ...s from your fire we recommend that it be serviced annually 7 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place 8 If you have any reason to...

Page 12: ...ger period d Depress control knob A slightly and turn anti clockwise to the ON position The main burner will not operate until this is done The main burner may light depending on the position of Contr...

Page 13: ...the DOWN button on the handset Release when the flame is at the desired height or has gone out Once again the electric motor should be heard moving Control Knob B Cleaning the fire Ensure that the app...

Page 14: ...wed of not smoking eating or drinking in the work area and that hands are washed before eating or drinking The appliance should be serviced at least once a year by a registered engineer and must inclu...

Page 15: ...After cleaning the glass door inside and out replace it and secure with the eight nuts Tighten the nuts evenly Stubborn marks can be removed with steel wool and detergent AFTER REFITTING THE APPLIANCE...

Page 16: ...he event of a part requiring replacement the parts list is as follows Part Description Part Number Motorised valve CV 104103 Remote hand control Receiver CV 104413 Pilot Burner NG Model CV 104506 Inje...

Page 17: ...17 B 124830 Issue 2 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com...

Reviews: