INSTALLATION INFORMATION

CONDITIONS OF INSTALLATION

It is the law that all gas appliances are installed only by a competent (e.g.

Registered) Installer, in accordance with the installation instructions and the Gas

Safety (Installation and Use) Regulations 1998. Failure to install appliances

correctly could lead to prosecution. It is in your own interest and that of safety to

comply with the law.

The fire may be fitted below a combustible shelf provided that the shelf is at least

200mm above the top of the appliance and the depth of the shelf does not exceed

150mm.

The fire may be installed below combustible shelves which exceed 150mm deep

providing that the clearance above the fire is increased by 15mm for each 25mm

of additional overhang in excess of 150mm.

No purpose made additional ventilation is normally required for this

appliance when installed in G.B. When installed I.E. please consult

document I.S. 813 : 1996 Domestic Gas Installation which is issued by the

National Standards Authority of Ireland. Any purpose made ventilation

should be checked periodically to ensure that it is free from obstruction.

If the chimney or flue has been previously used by appliances burning fuels other

than gas they must be swept prior to the installation of this fire.

If this appliance is fitted directly on to a wall without the use of a fireplace or

surround, soft wall coverings such as wallpaper, blown vinyl etc. could be affected

by the heat and hot convection air and may discolour or scorch. This should be

considered when installing or decorating.

The Model number of this appliance is as stated on the rating plate affixed to the

control panel of the fire and the appliance is manufactured by:-

BFM Europe Ltd

Trentham Lakes

Stoke on Trent

ST4 4TJ

2

Please Note : The life span of the batteries in the burner unit on SC / RC

variants is dependent upon use and therefore the battery life will vary

accordingly. If the burner unit fails to operate, please check the 6 off AA

batteries before calling the service centre for engineer assistance.

Summary of Contents for Ceasar

Page 1: ...should be read by the user before operating the appliance and retained for future reference Model No s KICC MN KICC SN KICC RN are only for use on Natural Gas G20 at a supply pressure of 20 mbar in G...

Page 2: ...6 Domestic Gas Installation which is issued by the National Standards Authority of Ireland Any purpose made ventilation should be checked periodically to ensure that it is free from obstruction If the...

Page 3: ...lderly and infirm Fireguards should conform to B S 8423 2002 Fireguards for use with gas heating appliances It is important that this appliance is serviced at least once a year by a registered gas ins...

Page 4: ...knob in for 5 10 seconds to allow the thermocouple to heat up if the pilot goes out when the control knob is released repeat the lighting sequence In the unlikely event of a failure of the igniter the...

Page 5: ...m downwards push to ensure that the f s d valve is fully latched if the pilot goes out when the control lever is released repeat the lighting sequence In the unlikely event of a failure of the igniter...

Page 6: ...and press the small flame button once An audible beep will be heard and the heat input level will reduce to the low setting 4 2kW Press and continually hold the small flame button and the fire will r...

Page 7: ...ill now remain in the off position until activated by the remote handset Fig 2 REPLACING THE BATTERIES REMOTE CONTROL MODELS ONLY ENSURE THE FIRE IS COOL BEFORE REPLACING BATTERIES Remove the ashpan c...

Page 8: ...that the fire has been allowed to fully cool CLEANING THE TRIMS AND PAINTED METAL PARTS Dependent upon the trim option chosen for use with this fire there is a variety of methods that can be chosen to...

Page 9: ...uelbed base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See fig 3 below Fig 3 b Position the two halves o...

Page 10: ...e recess s in the front ceramic rail as a guide for placement See fig 5 below Fig 5 d Select four of the large coals and arrange behind the front row of coals ensuring that flame paths as indicated be...

Page 11: ...he rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 7 below Fig 7 f Select the remaining four large coals and position to fill the gaps at each end of the...

Page 12: ...thene bag clearly labelled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is not requ...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...s are as follows these are available from BFM Europe who may be contacted at the address shown on the rear cover Fuelbed base B 58690 Fuelbed front rails L H R H B 18730 Replacement coal set B 61340 D...

Reviews: