kincrome KP87002 Manual Download Page 9

9

SMART 8 STAGE BATTERY CHARGER & 

MAINTAINER 12V 1.5 AMP

• 

Battery Analysis - BLUE LED ON

 

The battery analysis stage checks the condition of the battery after the charge cycle is 

completed. If the battery Voltage drops too quickly during the analysis mode, this means 

the battery is probably faulty. This is indicated by both the YELLOW charging LED and 

GREEN full LED being ON. 

• 

Float Mode - Full / Float GREEN LED ON

 

This stage allows you to keep the charger connected 24/7 to ensure your battery is well maintained 

and kept 100% fully charged. Float mode will maintain the battery at a constant 13.6V.

• 

Long Term Maintenance - Full / Float GREEN LED ON

 

During long term maintenance / float mode, the unit will apply a special pulse charge to 

ensure the battery is kept in optimal condition.

5.  Disconnecting the Battery charger from Battery

•  If the Battery is out of the vehicle:

  

(1) Switch OFF and Remove the AC Pin Plug from the outlet.

      

(2) Remove the BLACK lead and then the RED lead.

•  If  the battery is still in the vehicle:

  

(1) Switch OFF and Remove the AC Pin Plug from the outlet.

  

(2) Remove the lead from the vehicle chassis.

  

(3) Remove the lead from the battery.

Note: 

Check electrolyte levels if possible after charging as they may need topping up with distilled water. 

(This does not apply to sealed maintenance free batteries)

KP87002 OzCharge Manual.indd   9

5/03/2018   2:25 PM

Summary of Contents for KP87002

Page 1: ...ULLY PATENTED BATTERY REJUVENATION RECONDITIONING TECHNICAL EXPERIENCE N E E D E D NO 100 AUTOMATIC SMART BATTERY CHARGER MAINTAINER ANALYSIS BATTERY CONDITION MICROPROCESSOR CONTROLLED FULLY PATENTED...

Page 2: ...mperature 15 to 50 C Storage Temperature 25 to 85 C Operating Humidity 90 RH Max Dimensions 140 x 65 x 35mm Weight 0 45kg Approvals CE UL cUL AS NZS EMC Table of Contents Know Your Product 2 IMPORTANT...

Page 3: ...sh the eye with running cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or no...

Page 4: ...air sulphated batteries This feature is fully automatic and depends on the internal impedance of the battery It also depends on whether the battery is still connected in the vehicle Can be left on 24...

Page 5: ...me on This prevents the charger from being damaged if the positive and negative crocodile clips or ring terminals accidently touch each other while the charger is turned ON ECO MODE This Kincrome batt...

Page 6: ...REVERSE POLARITY CONNECTION RED FLASH SLOW AUTOMATIC REJUVENTATION OR CHARGE CYCLE HAS TIMED OUT RED FLASH FAST OVER TEMPERATURE PROTECTION MODE CHARGE RECONDITIONING LED BLUE YELLOW BLUE FLASH REJUV...

Page 7: ...ad acid sealed AGM GEL WET batteries Power Fault Charging Rejuvenation Reconditioning Full Float Smart 8 Stage Battery Charger Maintainer 12 VOLT DC OUTPUT 1 5 AMP CHARGE RATE RED BLACK RED BLACK CONN...

Page 8: ...e will break down and dissolve the lead sulphate crystal build up on the battery plates which will extend the life of your battery It can also balance out high concentrations of acid Note If the unit...

Page 9: ...6V Long Term Maintenance Full Float GREEN LED ON During long term maintenance float mode the unit will apply a special pulse charge to ensure the battery is kept in optimal condition 5 Disconnecting t...

Page 10: ...Australia Pty Ltd of 3 Lakeview Drive Caribbean Park Scoresby Victoria Tel 1300 657 528 The applicable warranty period 24 months commences on the date that the product is purchased If this product has...