BATTERY TESTER ANALYZER
5
7. Battery Test Result Examples
Good Battery (Fig. 8)
The battery is in good working condition.
Good, Recharge (Fig. 9)
Good battery but low current, recharge before using.
Replace (Fig. 10)
The battery is near to or already reached the end of it’s useful life.
Replace battery.
Bad Cell, Replace (Fig. 11)
Battery internal damage, bad cell or short circuit, replace battery.
Charge - Retest (Fig. 12)
Unstable battery, recharge and retest to avoid error.
If same test result appears after recharge and retest, the battery is
deemed as faulty, replace the battery.
Healthy: 96%
490CCA
Charge: 98%
12.64V
Internal R=6.1m Ω
Rated: 500A
GOOD BATTERY
Healthy: 78%
490CCA
Charge: 30%
12.20V
Internal R=7.2m Ω
Rated: 500A
GOOD, RECHARGE
Healthy: 46%
490CCA
Charge: 80%
12.68V
Internal R=18.1m Ω
Rated: 500A
REPLACE
Healthy: 0%
0CCA
Charge: 20%
10.64V
Internal R=45.2m Ω
Rated: 500A
BAD CELL, REPLACE
Healthy: 39%
310CCA
Charge: 20%
12.08V
Internal R=30.1m Ω
Rated: 500A
CHARGE - RETEST
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Summary of Contents for KP8501
Page 16: ...www kincrome com au...