13
Chapter 3 Interfaces and
Wiring
of
CD2S
Driver
3.1 Interfaces of
CD2S
Driver
3.1.1 Interfaces
Table 3-1 Interfaces of CD412S/CD422S/CD432S/CD622S
Interface
Driver
Symbol
Function
X1
CD412S
CD422S
CD432S
CD622S
COMI
Common terminal of digital inputs
DIN1
~
DIN7 Digital inputs. Valid signal:12.5V
~
24V.Invalid signal:<5V
OUT1+
Digital output 1+
OUT1-
Digital output 1-
OUT2+
Digital output 2+
OUT2-
Digital output 2-
OUT3
Digital output 3
OUT4
Digital output 4
COMO
Common terminal of digital outputs
GND
Ground signal
ENCO-Z
Motor encoder output interface
ENCO-/Z
ENCO-B
ENCO-/B
ENCO-A
ENCO-/A
AIN1
Analog signal input 1. Input impedance: 200 K
GNDA
Ground signal of analog
AIN2
Analog signal input 2. Input impedance: 200 K
GNDA
Ground signal of analog
PUL+
Pulse or positive pulse
interface (+)
Input voltage range
:
3V
~
24V
PUL-
Pulse or positive pulse
interface (-)
DIR+
Direction or negative pulse
interface (+)
DIR-
Direction or negative pulse
Summary of Contents for CD2S Series
Page 7: ...7...
Page 8: ...8 1 3 3 Power Brake and Encoder cable of Motors...
Page 12: ...12 Fig 2 3 Installation direction...
Page 15: ...15 3 1 2 Wiring Diagram Fig 3 1 Wiring diagram of CD2S driver...
Page 23: ...23 Fig 4 3 Separate regulation of bits...
Page 82: ...82...
Page 96: ...96 8 4 Debugging example 8 4 1 Oscilloscope 1 Enter oscilloscope 2 Parameters for Oscilloscope...
Page 98: ...98 In Auto Reverse mode Kvp 110...
Page 100: ...100 The oscilloscope is as following max following error is 69 inc Fig 2 Kpp 30 Vff 100...
Page 101: ...101 The oscilloscope is as following max following error is 53 inc Fig 3 Kpp 30 Vff 50...
Page 102: ...102 The oscilloscope is as following max following error is 230 inc...