a larger plywood surface to distribute the weight) must be attached to the wall prior to
installing the HAB™.
If you are anchoring into concrete or masonry, the minimum strength of the concrete
must be at least 2500 PSIwhile the minimum strength of the masonry must be at least
1500 PSI. Drill holes into the concrete or masonry with the 12 mm drill bit at the marks
you made earlier. Hammer the included M8* 30 mm expansion screws into the wall.
Attach the plate onto the wall with the M8 bolts.
Securing the HAB™
The HAB™ is heavy. It is approximately 230 lbs, and may cause serious back injury.
Use multiple people and/or lifting equipment to stably lift the HAB™ until the unit’s
upper and lower mounting flanges are just above the mounting plate’s upper and
lower lips and the HAB™ is between the mounting plate's arms. We strongly
recommend using lift equipment and straps to secure and steady the HAB™ during
installation.
Lower the HAB™ onto the mounting plate’s upper and lower lips, making sure that both
of the HAB™ unit’s upper and lower mounting flanges securely rest on both of the
mounting plate’s upper and lower lips. The holes in the mounting plate’s arms should
align with the lift handle screw holes. Attach the HAB™ to the mounting plate “ears”
using the included M8*16 mm bolts.
KiloVault
®
LLC • 330 Codman Hill Road, Boxborough, MA 01719 • +1 (888) 218-5924 •
•
5 of 9