background image

 

 

a larger plywood surface to distribute the weight) must be attached to the wall prior to 
installing the HAB™. 
 
If you are anchoring into concrete or masonry, the minimum strength of the concrete 
must be at least 2500 PSIwhile the minimum strength of the masonry must be at least 
1500 PSI. Drill holes into the concrete or masonry with the 12 mm drill bit at the marks 
you made earlier. Hammer the included M8* 30 mm expansion screws into the wall. 
Attach the plate onto the wall with the M8 bolts. 
 

Securing the HAB™ 

The HAB™ is heavy. It is approximately 230 lbs, and may cause serious back injury. 
Use multiple people and/or lifting equipment to stably lift the HAB™ until the unit’s 
upper and lower mounting flanges are just above the mounting plate’s upper and 
lower lips and the HAB™ is between the mounting plate's arms. We strongly 
recommend using lift equipment and straps to secure and steady the HAB™ during 
installation. 
 
Lower the HAB™ onto the mounting plate’s upper and lower lips, making sure that both 
of the HAB™ unit’s upper and lower mounting flanges securely rest on both of the 
mounting plate’s upper and lower lips. The holes in the mounting plate’s arms should 
align with the lift handle screw holes. Attach the HAB™ to the mounting plate “ears” 
using the included M8*16 mm bolts. 

 

 

KiloVault

®

 LLC • 330 Codman Hill Road, Boxborough, MA 01719 • +1 (888) 218-5924 • 

[email protected]

 • 

www.kilovault.com

 

5 of 9 

Summary of Contents for HAB V3 Addendum

Page 1: ...lar Battery V3 Addendum Please note This document only contains information specific to the HAB V3 pictured above For complete instructions please refer to the complete HAB Installation and Operation...

Page 2: ...te 2 Crate Contents 3 Install the HAB Mounting Plate 4 Mounting Surface 4 Securing the HAB 5 Connect the HAB to Your Inverter 6 Physical Specifications 8 KiloVault LLC 330 Codman Hill Road Boxborough...

Page 3: ...he case has integrated handles that fold completely out of the way when they re not needed The HAB now comes with vents that can be replaced with the included solid plates In cooler environments repla...

Page 4: ...the tabs at the bottom along the sides of the box and remove the box from the pallet rather than removing the top lid and lifting the HAB with the handles Part Quantity 1 5 meter HAB to HAB CAN Bus co...

Page 5: ...nch thick Use four one at each corner 14 1 4 wood screws with washers The screws must be long enough to penetrate at least inch beyond the back of the plywood You can also use four one at each corner...

Page 6: ...ple people and or lifting equipment to stably lift the HAB until the unit s upper and lower mounting flanges are just above the mounting plate s upper and lower lips and the HAB is between the mountin...

Page 7: ...cess port on the top of the HAB Two large and two small strain reliefs are included in the HAB packaging Simply remove the plugs from the access ports you want to use and replace them with the strain...

Page 8: ...complete HAB installation instructions They can be downloaded from www kilovault com KiloVault LLC 330 Codman Hill Road Boxborough MA 01719 1 888 218 5924 info kilovault com www kilovault com 7 of 9...

Page 9: ...286 lb 130 kg gross HAB Height 32 in 812 8 mm HAB Width 22 5 in 571 5 mm HAB Depth 9 2 in 233 7 mm Mounting Plate Height 18 in 458 1 mm Mounting Plate Width 22 3 in 565 5 mm Mounting Plate Ears 1 7 i...

Reviews: