ENVIROMENTAL

All  batteries  contain  toxic  compounds;  disposal  of  batteries  should  be
delegated  to  a  competent  organization,  complying  with  the  deposit  of
Poisonous Waste Regulation 1972.
Do not incinerate batteries.
The optimum operating temperature for the scale is 5°C to +35°C; although it
will  operate  at  higher  and  lower  temperatures  the  scale’s  battery  life  will  be
adversely effected.

CLEANING

We would recommend using alcohol based wipes or similar when cleaning the
scales.
Do not use large amounts of water when cleaning the scales as this will cause
damage to the scales electronics. You should also refrain from using corrosive
liquids or high-pressure washers.
Always  disconnect  the  scales  from  the  electrical  power  supply  before
cleaning.

MAINTENANCE

The  scale  does  not  require  any  routine  maintenance.  However,  we
recommend checking the scale’s accuracy at regular intervals. The regularity
of these checks is dependent on the level of use and the state of the scale. If
any inaccuracies occur, contact your local dealer.

WEIGHING OPERATION

Before reading detailed instructions on how to use  all  the  weighing  functions
that are built into your scale, please read the following important guidelines:
Always be sure that the display shows `Zero` before use, if it does not then
press the ZERO key.
The Professional Medical scale is designed to detect when a stable weight is
achieved. The indicator will `beep` twice to indicate a stable weight value, your
reading should be taken at this point.

WARRANTY-LIABILITY

Charder  medical  scales  sold  by  a  Kilotech  Inc.  authorized  dealer  are
warranted  for  2  years  from  the  original  date  of  purchase  and  only  to  the
original end user.  Kilotech may request a copy of the original invoice prior to
making any repair on warranty.
Charder  medical  scales  sold  by  a  Kilotech  Inc.  are  warranted  against
manufacturer  defects  under  normal  use.    The  warranty  does  not  cover  the
following:  unsuitable  or  improper  storage,  installation,  use  or  maintenance;

Summary of Contents for MS-4201 Baby

Page 1: ...MS 4202L Adult MS 4201 Baby USER MANUAL...

Page 2: ...4445 TABLE OF CONTENTS PREFACE 2 GENERAL INFORMATION 2 SAFETY INSTRUCTION 2 ENVIROMENTAL 3 CLEANING 3 MAINTENANCE 3 WEIGHING OPERATION 3 WARRANTY LIABILITY 3 DISPOSING OF THE SCALE 4 SPECIFICATIONS 5...

Page 3: ...and maintenance of the device The end user must take every precaution to insure the safety of this device and the people using the device Neither Kilotech Inc nor the manufacturer shall be liable for...

Page 4: ...regularity of these checks is dependent on the level of use and the state of the scale If any inaccuracies occur contact your local dealer WEIGHING OPERATION Before reading detailed instructions on h...

Page 5: ...k and return the scale to Kilotech and is responsible for any damage caused to the device because of improper packaging An RMA Return Merchandise Authorization Number must be obtained prior to shippin...

Page 6: ...lb 200kg x 50g 440lb x 0 1lb Tray Yes No Units of Measure kg lb Function keys ON ZERO OFF HOLD BMI TARE Stabilisation Time 1 2 seconds Operating Temp 0 C 40 C at 80 RH Power supply Six AA size alkalin...

Page 7: ...6 SETTINGS Auto Off Time Adjustment Auto Off time feature affects how long will shut off automatically without any operation Press TARE key for 3 seconds to enter setting mode Press...

Page 8: ...1 Press ZERO for 3 seconds to enter setting mode 2 Press TARE when A_OFF displayed 3 Press HOLD to select target time 60 120 240 300s OFF 4 Confirm your selection by pressing TARE again 5 Press HOLD...

Page 9: ...be 50 cm 1 Press this key once to enter HOLD mode to lock weight value when weighing 2 Proceed with weighting Scale will beep when it has a stable reading and the hold indicator 7 is active 3 Press H...

Page 10: ...y protective paper or napkin placed in the bowl can be deducted by pressing TARE key and obtaining zero Baby can then be weighed 4 Zero symbol 5 ON ZERO OFF MS 4201 MS 4202 MS 4202L only 6 Level indic...

Page 11: ...10 INSTRUCTION FOR REPLACING BATTERY REMOVE THE BATTERY COVER ON BOTTOM SIDE OF SCALE PLEASE BE CAREFUL OF CORRECT BATTERY DIRECTIONS WHILE INSTALLATION...

Page 12: ...11 INSTALL 6 1 5V AA BATTERIES YOU CAN ALSO USE THE ADAPTOR TO SUPPLY THE POWER...

Page 13: ...f the trouble still exists please call your local service partner The loading is under limit when power on please reduce the loading If the trouble still exists please call your local service partner...

Page 14: ...13 IN 0991 7008D...

Reviews: