General Precautions 

Avoid lengthy exposure to heat 
or cold.

 

Allow the scale to acclimate to normal room temperature before 
use.

 

Allow sufficient warm up time.

 

Turn the scale on and wait for a few minutes to allow the internal 
components a chance to stabilize before weighing.

 

Do not leave a load or weight 
on a scale for a prolonged 
period of time.

 

  

Do not tamper with the scale 
yourself.

 

This will void the warranty. Contact your local distributor to 
properly repair your scale.

 

Do not dissemble the scale 
yourself.

 

This will void the warranty. Contact your local distributor to 
properly repair your scale.

 

Do not load beyond max cap 
the maximum weight limit.

 

  

Do not pull the plug by its cord 
when unplugging.

 

  

Do not use the scale near fire 
or corrosive gas.

 

  

Do not spill water or immerse 
in water.

 

  

Avoid placing the scale near a 
heater.

 

It could cause a fluctuation to the indicator reading.

 

Always make sure to use a 
Kilotech approved adapter.

 

  

Do not drop the scale or apply 
a sudden shock.

 

  

Do not drag the scale.

 

  

Avoid exposing to other 
electromagnetic devices.

 

These devices emit RF and can cause unstable readings. If your 
scale should perform poorly, try moving the scale to a different 
room or location.

 

Level the scale or make sure it 
is on an even surface.

 

A scale used on an uneven surface may provide an unstable 
reading.

 

Scale should be used within 
stated temperature & humidity 
limits.

 

  

Do not disassemble or modify 
the scale, since this voids the 
warranty

 

 

 

 

 

Summary of Contents for KPC 15K

Page 1: ... Owner s Manual KPC 3K AND KPC 15K OPERATION MANUAL E MAN08152022 Ce manuel est disponible en français à http www kilotech com K850137 KPC 3K 3KG X 0 1G 6LB X 0 0002LB GTIN 889605250137 K850138 KPC 15K 15KG X 0 5G 30LB X 0 001LB GTIN 889605250138 ...

Page 2: ...efects in material and workmanship for a period of one year for the scale and 3 months for the adapter from the date of purchase Please retain your receipt as proof of purchase Warranty expiration on products returned without proof of purchase will be determined from the manufacturing date code or the date of shipment to the authorized dealer Coverage may be invalidated as this date is previous to...

Page 3: ...ad beyond max cap the maximum weight limit Do not pull the plug by its cord when unplugging Do not use the scale near fire or corrosive gas Do not spill water or immerse in water Avoid placing the scale near a heater It could cause a fluctuation to the indicator reading Always make sure to use a Kilotech approved adapter Do not drop the scale or apply a sudden shock Do not drag the scale Avoid exp...

Page 4: ...power off function YES Zero tracking zero error indication overload alert function YES Error signal YES Counting Feature YES Power Input AC110V 240V 50HZ Output AC9V 12V 500mA DC 6V4Ah recharging battery Power dissipation 0 1VA Product Dimensions 26cm 10 25 x 20cm 8 x 8cm 3 25 Platter Size 20cm 8 18cm 7 Operating Temperature Humidity 0 40 85 RH Minimum load cell resolution 0 1uV Maximum resolution...

Page 5: ... battery should be fully charged for at least 12 hours Connect the supplied AC adapter to the power input receptacle underneath the scale Plug the AC adapter into a power outlet and the battery will begin charging If the scale will be stored or transported in the future save the packaging material to ensure the best possible protection for the scale Weighing operations KEYBOARD AND DISPLAY Front P...

Page 6: ...ress MODE to confirm and enter into next step 02 Press MODE bp On Buzzer On or OFF setting Press 0 to change data Press MODE to confirm and enter into next step 03 Press MODE Pr AB Backlight setting A 0 2 can be selected 0 backlight always off 1 when weighing and the weight is stable backlight will turn off after the numbers of seconds set in the B setting below 2 when zero displayed the backlight...

Page 7: ... X 1 means after stable status data sent out 05 Press MODE PLo 20 Rechargeable battery use setting Press MODE to skip this step and enter into next step Press 0 to change setting digits 0 40 can be selected Ex 20 means when rechargeable battery indicator is 20 scale will power off automatically Press MODE to confirm and enter into next step 06 Press MODE LCd 5 LCD brightness setting Number 3 15 ca...

Page 8: ...ng stable lock setting X 0 unlocking X 1 locking after common stable X 2 press 0 to lock and unlock X 3 weight value of buzz locking press 0 to unlock Press 0 key to change data Press MODE to confirm and enter into next step Press MODE FLT1 X Locking time setting only FLTO 1 effective X 0 means after stable locking X 1 9 means after weighing stable 1 9 seconds locking Press 0 key to change data Pr...

Page 9: ... SP Calibration status setting 02 Press T CAL 0 Enter into calibration status 03 Press MODE 1 Entering auto zero calibration after then indicator show the max capacity ex 15000g 04 Press MODE XXXXXX eg 10000g When Max Capacity weight display ex 15000g Load the test weight 1 3 max Capacity ex 10000g After stable symbol STB display Press T to select digit position and press 0 to set the digits from ...

Page 10: ...on the pan ex 50 pieces After the icon is displayed press and hold the MODE key for three seconds The display will read 000000 and the PCS icon will be active Press T to select the position and 0 to set the sample size until the display reads 000050 Then press MODE to see n 50 displayed You may need to add more items if you get the Err 11 code since the weight of the item may be too light or out o...

Reviews: