20
3.
Set function options and operating instructions
3-1.
After the power is turned on, press the "E / C" button for 3 seconds to enter the menu of initial
default, which must entry the password to enter.
LOAD DEFAULT NO/DEFAULT
Cancel/restore to factory setting
NO
3-2.
The status “LC” is displayed on the 7-segment display when key lock has been used.
Un: Key of unlock state
LC: Key of lock state
3-3.
After the power is turned on, press the "P" button for 3 seconds to enter the Function menu page,
which must entry the password to enter.
3-4.
After enter the function menu page, parameter can be browsed and setting by press up and down
button.
4. External Input Control Function Description
Connector No.
Definition
Function Description
CN 1
External start signal input
START_IN
1. When (CN1+GND) is in close circuit (CLOSE), the screwdriver then Starts.
2. When (CN1+GND) is in open circuit (OPEN), the screwdriver then Stops.
CN 2
GND
Output GND.
CN 3
External reverse rotation
signal input
REVERSE
1. External switch-on (CN1) is in close circuit with GND (CLOSE); during the
reverse rotation signal (CN3+GND) Close (CLOSE), the screwdriver then
starts the activation of Reverse rotation.
2. External switch-on (CN1) is in close circuit with GND (CLOSE); during the
reverse rotation signal (CN3+GND) Open (OPEN), the screwdriver then
starts the activation of Forward rotation.
CN 4
GND
Output GND.
CN 5
External disable signal input
DISABLE
1. When (CN5+GND) is in close circuit (CLOSE), the screwdriver cannot be
activated.
2. When (CN5+GND) is in open circuit (OPEN), the screwdriver can be
activated.
CN 6
GND
Output GND.
CN 7
External confirm key input
CONFIRM
1. When the system requires the press of confirmation key, the CN7 in close
circuit with GND can be used instead.
2. After executing the CONFIRM, the NG signal is also cleared.
CN 8
GND
Output GND.
CN 9
External confirm key input
CLEARED
To clear the count value, the CN9 in close circuit with GND can be used to
clear count value.
CN 10
GND
Output power GND.
CN 11
External sensor switch
GATE
1. Input a confirmation signal to allow the controller to determine that the
workpiece is in position.
2. Sensor switch: external switch in operation can be connected to one or two
switches.
3. Connection to any switch shall be connected to GND (CN14).
CN 12
GND
Output GND.
CN 13
SEQUENCE CLEARED
When the sequence is to be cleared, this function can be triggered by CN13 to
GND connected. (CN13+GND)
CN 14
GND
Output GND.