30
TOS5200
Forbidden Actions
Turning the power on and off repeatedly
After you turn the POWER switch off, wait for at least 10 seconds before you turn it back on.
It is dangerous to do otherwise, because the protective features of the product may not work
effectively. This may cause the product to malfunction, and it may reduce the life of the
POWER switch and internal parts such as the fuses.
About Malfunctions
If the TOS5200 is in one of the states explained below, it may be malfunctioning in a very
dangerous manner—it may not be possible to turn off the high voltage that is being gener-
ated. If the tester is not operating properly, it may be generating a high voltage irrespective of
the settings made by the operator.
Immediately turn the POWER switch off, and disconnect the power cord from the outlet. Stop
using the product immediately, and contact your Kikusui agent or distributor.
●
Even when you press the STOP switch, the DANGER LED remains lit.
●
During tests, the DANGER LED does not light.
To Use the Product for a Long Time Free of Malfunctions
Taking size, weight, and cost into consideration, the heat dissipation capability of the voltage
generator that is used for withstanding voltage tests has been designed to be one half that of
the rated output. Use the TOS5200 within the following limits. If you use the product in a man-
ner that exceeds these limits, the output section may overheat, and the internal protection cir-
cuits may be activated. If this happens, stop testing, and wait until the TOS5200 returns to its
normal temperature.
■
Output limits during withstanding voltage testing
(Output time = voltage rise time + test time + voltage fall time)
WARNING
Risk of electric shock.
• Until you get the product fixed, make sure that nobody can use it.
• For repairs, contact your Kikusui agent or distributor.
Ambient temperature
Upper limit
Pause time
Output time
t
≤
40 °C
50 mA < i
≤
110 mA
Greater than or equal to
the output time
30 min. max.
i
≤
50 mA
Not necessary
Continuous output possible
Summary of Contents for TOS5200
Page 7: ...TOS5200 7 C Test Start Operation and Display 75 D Troubleshooting 76 Index 79 ...
Page 18: ...18 TOS5200 This page is intentionally blank ...
Page 19: ...Installation and Preparation This chapter describes how to prepare this product for use ...
Page 60: ...60 TOS5200 This page is intentionally blank ...
Page 61: ...Maintenance This chapter explains daily inspections such as measurement checks ...
Page 78: ...78 TOS5200 This page is intentionally blank ...
Page 80: ...80 TOS5200 V version 2 Volt Error Protection 74 W W COMP 32 40 warm up time 64 ...
Page 81: ......