Specifications
Unless specified otherwise, the specifications are for the following settings and conditions.
• Loads are purely resistive loads.
• The product is warmed up for at least 30 minutes.
• The negative output is connected to the chassis terminal with a short bar.
• Values indicated by “TYP” are typical values. These values do not guarantee the performance of the
PMX seres (multiple-output).
• rating: Indicates the rated.
• set: Indicates a setting.
• reading: Indicates the readout value.
• Rated load and no load are defined as follows:
In constant-voltage mode (when the output current is set to a value greater than or equal to the maxi-
mum output current with rated output voltage)
Rated load: Refers to a resistive load that, when the rated output voltage is applied, makes the
flowing current 95 % to 100 % of the maximum output current with rated output volt-
age.
No load:
Refers to a load through which no output current flows. In other words, refers to an
open load (no load being connected).
In constant-current mode (when the output voltage is set to a value greater than or equal to the maxi-
mum output voltage with rated output current)
Rated load: Refers to a resistive load that, when the rated output current flows, makes the voltage
drop to 95 % to 100 % of the maximum output voltage with rated output current.
Including the voltage drop in the load cables, the product’s output voltage must not
exceed the maximum output voltage with rated output current.
No load:
Refers to a resistive load that, when the rated output current flows, makes the voltage
drop to 10 % of the maximum output voltage with rated output current or 1 V whichever
is higher.
AC input
PMX32-3DU
PMX32-3TR
PMX32-2QU
Nominal input rating
217 Vac
*1
, 50 Hz/ 60 Hz, single phase
*1.
100 Vac, 117 Vac, 200 Vac, and 234 Vac are factory options.
Input voltage range
± 10 %
Input frequency range
47 Hz to 63 Hz
Inrush current (MAX)
*2
*2.
Excludes the charge current component that flows through the capacitor of the internal EMC
filter circuit immediately after the POWER switch is turned on (for approximately 1 ms).
150 A
150 A
150 A
Power (MAX)
700 VA
900 VA
800 VA