PMX_MULTI
User’s Manual
47
Basic Functions | CONFIG Settings
CF08 (
A.OFF
)
Output state when a protection function (OVP/OCP) is acti-
vated
Sets the output state when a protection function (OVP/OCP) is activated
When the output-on delay/ off delay time is set, the output of all channels turns off regardless of the set-
ting.
CF09 (
DTRC
)
Tracking operation
Enables or disables the tracking operation
. Can be set separately for each channel.
Set this so that at least two channels have the tracking operation turned on. You cannot specify less than
two channels.
CF20 (
LAN
)
LAN interface
Enables or disables the LAN interface.
Setting this parameter to “
OFF
” disables the LAN interface function even when a LAN cable is connected.
To apply the setting, turn off the power and then turn it back on.
CF21 (
USB
)
USB interface
Enables or disables the USB interface.
Setting this parameter to “
OFF
” disables the USB interface function even when a USB cable is connected.
To apply the setting, turn off the power and then turn it back on.
Display
Description
SELF
SELF
The output is turned off only on the channels on which an alarm
occurs.
ALL
ALL
The output of all channels is turned off (factory default setting).
Display
Description
OFF
OFF
Tracking operation is disabled.
ON
ON
Tracking operation is enabled.
Factory default
settings
Model
CH1
CH2
CH3
CH4
PMX32-3DU
ON
ON
−
−
PMX32-3TR
ON
ON
OFF
−
PMX32-2QU
ON
ON
OFF
OFF
Display
Description
OFF
OFF
LAN disabled
ON
ON
LAN enabled (factory default setting).
Display
Description
OFF
OFF
USB disabled
ON
ON
USB enabled (factory default setting).