PLZ-4WL
115
Specifications
7
S
pec
ifi
cati
ons
General specifications
Model
PLZ164WL
PLZ334WL
Input voltage range
100 Vac to 240 Vac (90 Vac to 250 Vac), single phase, continuous
Input frequency range
47 Hz to 63 Hz
Power consumption
95 VA max
Inrush current
1
1
Approx. 35 A when receiving an input of 100 Vac
65 Amax
Operating temperature range
0
C to 40
C (32
F to 104
F)
Operating humidity range
20 %rh to 85%rh (no condensation)
Storage temperature range
-20
C to 70
C (-4
F to 158
F)
Storage humidity range
90 %rh or less (no condensation)
Isolation voltage
±500 V
Insulation
resistance
Primary to input terminal
500 Vdc, 30 M
or more (ambient humidity of 70 %rh or less)
Primary to chassis
500 Vdc, 30 M
or more (ambient humidity of 70 %rh or less)
Withstand
voltage
Primary to input terminal
No abnormalities at 1500 Vac for 1 minute
Primary to chassis
No abnormalities at 1500 Vac for 1 minute
Dimensions (mm)
See the outline drawing.
Weight
Approx. 6.5 kg (14.3 lb.)
Approx. 8 kg (17.6 lb.)
Battery backup
Backs up setup information
Accessories Power cord
1 pc. (with plug, length: 2.4 m)
Load input terminal cover
1 pc.
Set of screws for the load
input terminal cover
2 sets
Set of screws for the load
input terminal
2 sets
Chassis connection wire
1 pc.
CD-R
1 pc.
Setup Guide
1 pc.(Japanese, English)
Quick Reference
English: 1pc., Japanese: 1pc.
Safety
2
2
Does not apply to specially made or modified PLZ-4WLs.
Complies with the requirements of the
following standard.
IEC 61010-1:2001
(Class I
3
, Pollution degree 2
4
)
3
This is a Class I product. Be sure to ground this product’s protective conductor terminal. The safety of this product is only
guaranteed when the product is properly grounded.
4
Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface
resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary
conductivity caused by condensation.
Complies with the requirements of the
following directive and standards.
Low Voltage Directive 2014/35/EU
5
EN 61010-1 (Class I
5
Limited to products that have the CE mark on their panels. Not be in compliance with EMC limits unless the ferrite core is
attached on the cable for connection of J1 connector.
Electromagnetic compatibility (EMC)
–
Complies with the requirements of the
following directive and standards.
EMC Directive 2014/30/EU
EN 61326-1 (Class A
6
)
EN 55011 (Class A
, Group 1
7
)
EN 61000-3-2
EN 61000-3-3
6
This is a Class A equipment. This product is intended for use in an industrial environment. This product may cause interference
if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic
emissions to prevent interference to the reception of radio and television broadcasts
7
This is a Group 1 equipment. This product does not generate and/or use intentionally radio-frequency energy, in the form of
electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose.
Applicable under the Following Condition
The maximum length of all cabling and
wiring connected to the PLZ-4WL must
be less than 3 m.