46
PFX2512
Configuring the PFX2512
Setting the channel numbers
To use the PFX2512, you need to set a unique number called channel number to identify the
PFX2512 and also to set the IP address. If you are using only a single PFX2512, you do not need to
set the channel number.
Tests can be performed under different conditions for each channel number.
Assign a unique number to each PFX2512.
Setting the vibration sensor
The PFX2512 has a built-in vibration sensor.
If set to on, when the PFX2512 detects large shaking (around magnitude 5 and higher) or shock
during charge / discharge testing, a SHOCK DETECT alarm will be activated, and the output will be
turned off. The vibration sensor sensitivity is fixed.
Set it before turning on the power.
To release the alarm caused by the vibration sensor, execute an alarm release command from
BPChecker3000.
Valid channel numbers
1 to 7
SH DET switch
Vibration sensor
0
Off (factory default setting)
1
On
• The vibration sensor is designed not to respond to single shock (such as bumping), but it may
abort a test due to vibration or shock other than earthquakes. Take this into consideration when
you turn on the vibration sensor (set the switch to 1).
• If you want to set the vibration sensor to on (set the switch to 1), install the PFX2512 as upright as
possible in a location without vibration or the like. If the installation is inappropriate, the SHOCK
DETECT alarm may be activated preventing you from performing tests.
Summary of Contents for PFX2500 Series
Page 12: ...12 PFX2512 This page is intentionally blank ...
Page 62: ...62 PFX2512 This page is intentionally blank ...
Page 71: ...Specifications This chapter provides the PFX2512 s specifications and outline drawing ...
Page 96: ...96 PFX2512 This page is intentionally blank ...
Page 140: ...140 PFX2512 Troubleshooting This page is intentionally blank ...
Page 143: ......