Configuring the Devices
Configuration procedure of devices
1
Set the channel numbers and vibration sensor using the S1 switch of the
PFX2512.
2
Configure the DC power supply.
Set protection functions, external analog control, and panel lock.
3
Configure the electronic load.
Configure the protection function, slew rate, external analog control, panel lockand if
necessary, parallel operation.
Configuring the PFX2512
You can change the following settings using the S1 switch on the rear panel. If you change a
setting, turn the PFX2512 off and then back on.
•
Channel numbers
•
Vibration sensor
See
See
See
Signal name
Logic
Notes
Factory
default
TERMN OFF
1
1
TP-BUS connector is not used on the PFX2512.
Not used
Always set to
ze
0
NC
Not used
Always set to
zero
0
1
Set channel numbers
(1 to 7).
0 is not allowed.
−
1
2
−
0
4
−
0
8
−
0
RESV
Not used
Always set to
zero
0
SH DET
0: Vibration sensor off
1: Vibration sensor on
−
0
Factory default switch position
Example of channel number 1
S1
SH DET
RESV
8421
NC
TERMN
OFF
1
0
Summary of Contents for PFX2500 Series
Page 12: ...12 PFX2512 This page is intentionally blank ...
Page 62: ...62 PFX2512 This page is intentionally blank ...
Page 71: ...Specifications This chapter provides the PFX2512 s specifications and outline drawing ...
Page 96: ...96 PFX2512 This page is intentionally blank ...
Page 140: ...140 PFX2512 Troubleshooting This page is intentionally blank ...
Page 143: ......