30
PFX2512
Connecting the Devices
The following example is consisting of the Charge/ Discharge System Controller PFX2512, DC
power supply PWR1201ML, the Electronic load PLZ1205W, and the DUT (battery).
The direction of leading cables of input / output terminal board can be either right or left angle.
However, wire the all the cables to become same directions as possible. Use the cable whichever it
comes as standard accessory.
For stable operation, reduction of noise effects, and prevention of malfunction, note the following.
•
Twist the + and - cables.
•
Do not bind or cross the cables.
•
Do not bind flat cables with cables for running current or pass them between cables.
The PFX2512 does not come with cables for connecting to the DUT (battery). Prepare the necessary
cables for each device.
There is an optional TL08-PFX cable set that contains cables for connecting the PFX2512 to the DUT
(battery).
Taking the current capacity into consideration, we recommend that you use cables with a nominal
cross-sectional area of at least 14 mm
2
.
■
Nominal cross-sectional area of wires and allowable currents (reference)
WARNING
Risk of electric shock.
There is no specific order in connecting the devices, but connect the DUT (battery) last. When
connecting the DUT (battery), connect the PFX2512 side first.
See
Nominal
cross-
sectional
area (mm
2
)
AWG
Reference cross-
sectional area
[mm
2
]
Allowable
current
1
[A](Ta = 30°C)
1
Excerpt from Japanese laws related to electrical equipment.
Kikusui-
recommended
current (A)
2
14
(2.08)
27
10
3.5
12
(3.31)
37
-
5.5
10
(5.26)
49
20
8
8
(8.37)
61
30
14
6
(13.3)
88
50
22
4
(21.15)
115
80
30
2
(33.62)
139
-
38
1
(42.41)
162
100
50
1/0
(53.49)
190
-
60
2/0
(67.43)
217
-
80
3/0
(85.01)
257
200
100
4/0
(107.2)
298
-
125
-
-
344
-
150
-
-
395
300
200
-
-
469
-
Summary of Contents for PFX2500 Series
Page 12: ...12 PFX2512 This page is intentionally blank ...
Page 62: ...62 PFX2512 This page is intentionally blank ...
Page 71: ...Specifications This chapter provides the PFX2512 s specifications and outline drawing ...
Page 96: ...96 PFX2512 This page is intentionally blank ...
Page 140: ...140 PFX2512 Troubleshooting This page is intentionally blank ...
Page 143: ......