16
PFX2512
System Configuration
The following figure shows a basic configuration example of a charge / discharge system that uses
the PFX2512. The system consists of a PFX2512, Kikusui’s DC power supplies and electronic loads,
and peripheral subsystems.
The PFX2512 functional block is mainly made up of a DUT voltage / current / temperature
measurement section, a digital constant current / constant voltage control section, a power supply
/ electronic load I / F section, a host communication control section, and a load switch.
The PFX2512 has an interface that directly connects to Kikusui’s power supplies and electronic
loads. The system is designed to allow full-scale charge / discharge testing with easy initial
configuration without extra equipment or external circuits.
The connection status of DC power supplies, electronic loads, and DUT (battery) is constantly
monitored. If a problem is detected in any of the devices, the charge / discharge test is safely
aborted.
The PFX2512 is controlled from a PC through the LAN interface.
Application software BPChecker3000 is used to configure and control charge / discharge test
conditions. For details on the application software, see the corresponding help file.
CC
SDRAM
measurement memory
Load Switch
LAN
CC/CV
+
+
+
+
+
+
+S
-S
BPChecker3000
ADC
Protection
control
Communication control
Isolator
Time base
Digital CC
control
Sequence
control
Digital CV
control
Digital CP
control
Pulse
control
Option communication
Current
measurement
V
oltage measurement protection
DUT
I/F
PFX2512
I/F
The load switch control
The applied
voltage of
each cell /
temperature
measurement
board (Option)
DAC
DAC
Indicator
Current detection
Votage sensing
Cell voltage
Cell
temperature
Votage
sensing
DC power
supply
Electronic
load
Analog I/F
Analog I/F
Charge / Discharge System configulation (Example)
BPChecker3000
Hardware configuration
Io Config
Test condition creation
Test Condition Editor
Test execution
Test Executive
Test result analysis
Graph Viewer
?
Help
Summary of Contents for PFX2500 Series
Page 12: ...12 PFX2512 This page is intentionally blank ...
Page 62: ...62 PFX2512 This page is intentionally blank ...
Page 71: ...Specifications This chapter provides the PFX2512 s specifications and outline drawing ...
Page 96: ...96 PFX2512 This page is intentionally blank ...
Page 140: ...140 PFX2512 Troubleshooting This page is intentionally blank ...
Page 143: ......