KIKUSUI Electronics Corp.
172
VOLT:COMP:MODE
Sets the compensation (voltage compensation).
Command
[SOURce:]VOLTage:COMPensate:MODE <character>
[SOURce:]VOLTage:COMPensate:MODE?
Parameter
Value:
DISabled Disables the compensation (default)
HARD
Enables hard sensing
SOFT
Enables soft sensing
RADJust
Enables regulation adjustment
Settings are reset to default values when an *RST command is sent.
Example
VOLT:COMP:MODE HARD
Response: Characters