KIKUSUI Electronics Corp.
126
PROG:EDIT:PHAS:STAR
Sets the starting phase angle and whether to suddenly change the phase of the se-
quence step.
Command
PROGram:EDIT:PHASe:STARt <step_NRf>,<enable_boolean>[,<phase_
NR3>[,<phase_change_boolean>]]
PROGram:EDIT:PHASe:STARt? <step_NRf>
Parameter
<step_NRf>
Value: 0 to 599 Number of the step that you want to configure
Parameter
<enable_boolean>
Value:
ON(1)
Enables phase control
OFF(0) Disables phase control (default)
Parameter
<phase_NR3>
Value:
0.0 to 360.0
Starting phase angle (The default value is 0)
0 and 360 are the same.
Unit:
DEG
Parameter
<phase_change_boolean>
Value:
ON(1)
Enables sudden phase change
OFF(0) Disables sudden phase change (default)
Example
PROG:EDIT:PHAS:STAR 1,ON,90,OFF
PROG:EDIT:PHAS:STAR? 1
Response
Returns the starting phase angle and the sudden phase change setting of the spec-
ified step in the following order.
Phase control enabled/disabled<NR1>, starting phase angle<NR3>, sudden phase
change setting<NR1>