To turn the output on
Single-phase output
1.
Set the Output Mode.
Press OPR MODE and then ACDC (F2) to
select the output mode.
2.
Set the output voltage mode.
Press RANGE(SHIFT+8) to select the
output voltage range.
You cannot set the mode if the output is
turned on.
3.
Set the output voltage.
To set the AC voltage, press V and then
ACVOLT(F1). To set the DC voltage, press
V and then DCVOLT(F2).
4.
Set the frequency. (AC/ AC+DC
mode only)
Press F and then FREQ(F1).
5.
Turn the OUTPUT on.
Press the OUTPUT key.
List of function keys
Key
Standard function
Key
Standard function for the PCR-LE2,
option for the PCR-LE
Key
Option
Some items may not be displayed depending on how
the product is configured.
V key
ACVOLT
AC voltage
DCVOLT
DC voltage
UV PHASE
U-V phase difference
UW PHASE
U-W phase difference
PHAS VOLT*1
Voltage of all the phases
U VOLT*1
Voltage of U phase
V VOLT*1
Voltage of V phase
W VOLT*1
Voltage of W phase
LINE VOLT*1
Line voltage
PROTECT OVP
Output overvoltage protection
UVP Output undervoltage
protection
VMAX
Voltage upper limit
VMIN
Voltage lower limit
*1. Use the following soft keys when AC+DC is selected.
Setting of AC voltage
AC PH VOLT Voltage of all the phases
U ACVOLT
Voltage of U phase
V ACVOLT
Voltage of V phase
W ACVOLT
Voltage of W phase
AC LIN VOLT Line voltage
Setting of DC voltage
DC PH VOLT Voltage of all the phases
U DCVOLT
Voltage of U phase
V DCVOLT
Voltage of V phase
W DCVOLT
Voltage of W phase
F key
FREQ
Frequency
FMAX
Frequency upper limit
FMIN
Frequency lower limit
I key
ILIMIT
Current limit
+IPKLIM Positive peak limit
-IPKLIM Negative peak limit
TRIP
Action to perform when the limit is
exceeded
TRIP
TIM
Time that elapses after the limit is
exceeded until the output is turned off
OCP
TIM
Time that elapses after the
semiconductor protection function is
activated until an alarm is generated
V-MEAS (SHIFT+V) key
RMS
Displays the rms voltage
PEAK Displays the peak voltage
AVE
Displays the average voltage
LINE
Switches between line voltage and
phase voltage
I/P/S/
λ
-MEAS (SHIFT+I) key
RMS
Displays the rms current
PEAK
Displays the peak current
AVE
Displays the average current
P
Displays the power
PKCLR
Clears the peak current
S
Displays the apparent power
λ
Displays the power factor
TOTAL P
Displays the total power
TOTAL S
Displays the apparent power
TOTAL
λ
Displays the total power factor
IPK TIM
The hold time
MEMORY key
RCL No. Recalls settings from memory
STR No. Stores settings in memory
OTHER (SHIFT+MEMORY) key
RISETIM
Soft start
WAVE
WB No.
Number of the waveform
bank to execute
EDIT
WB No. Number of the
waveform bank to edit
SIN
Sine wave
P.C
Crest factor
OUT IMP
Output impedance
FFT
ALL
All orders
ODD
Odd-numbered orders
EVEN
Even-numbered orders
AMPER
Unit that is used to display
the harmonic components
PCT
U
Selects the U phase
V
Selects the V phase
W
Selects the W phase
VCC
Internal Vcc, fixed or
automatic
COMPEN
Compensation function
RESP
Response
PON OUTP
Output status when the
power is turned on
FILE LOAD
Recalls settings from a
USB memory device
SAVE
Saves data to a USB
memory device
APERTUR
Aperture time
EXT SIG
SOUR
Signal source (EX05-
PCR-LE)
POL
Polarity
VPROG
Signal source (EX06-
PCR-LE)
SLEEP (SHIFT+1) key
ON/ OFF Sleep function
EXEC
Starts the sleep function instantly
OFF PHASE (SHIFT+4) key
Output off phase control
ON PHASE (SHIFT+7) key
Output on phase control
RANGE (SHIFT+8) key
Output voltage range
SYNC (SHIFT+9) key
ON/ OFF Synchronization function
DELAY
Synchronization delay phase angle
CONFIG (SHIFT+ OPR MODE) key
COM
-I/F
TRACE
Error display
TYPE RS
232C
BAUDRATE
Baud rate
DATABITS
Data length
STOP BITS
Stop bits
FLOW
CTRL
Flow control
GPIB ADDRESS
GPIB address
USB
USB
LAN
DHCP
LAN CONFIG
display and
DHCP function
AUTO IP
LAN CONFIG
display and
automatic
IP address
assignment
MANUAL
IP
LAN CONFIG
display and
manual IP
address
assignment
SIG.I/O
TRIG.IN
Trigger input
polarity
TRIG.OUT
Trigger output
polarity
STAT.OUT
Status output
polarity
DISPLAY
INTEN
Screen brightness
adjustment
MODEL ID
Model information
display
DATE TIM
Date and time
SURGE S
Voltage surge
suppression
EXT.
OPT
CONTROL OUTP ON
Controlling the
Output On/ Off
SEQ RUN
Sequence
execute/ stop
ALMCLR
Alarm clear
SHUT-
DOWN
Shut down the
output
STAT.OUT
Selecting the
phase to monitor
PHASE (SHIFT+F) key
Switches the phase to display
OPR MODE key
ACDC
Output voltage mode
POW SAV
Power-saving function
2P*1
Output mode
WIRING*2
Output mode
*1. PCR-LE optional only
*2. PCR-LE2 only
SIM key
RUN
Execute
STOP
Stop
LOOP
Number of repetitions
COND POL
Voltage regulation polarity
T1 TYPE Voltage regulation starting
setting type
T5 TYPE
Return state hold setting type
EDIT
T1
Voltage regulation starting
time or phase
T2
Slope time 1
T3
Voltage regulation time
T4
Slope time 2
T5
Return time or the number
of return cycles
T3 VOLT Regulated voltage
SEQ (SHIFT+SIM) key
RUN
Executes
STOP
Stops
PAUSE
Pauses
CONTINUE
Unpauses
LOOP
Number of repetitions
COND
START STEP Starting step number
END STEP
Ending step number
EDIT
STEP
Step number
FREQ
Frequency
RAMP
Signal change
ACVOLT
AC voltage
RAMP
Signal change
ACV V
AC voltage of V phase
ACV W
AC voltage of W phase
TIME
Time
WB NO
Waveform bank number
OUTPUT
Output
DCV
DC voltage
RAMP
Signal change
DCV V
DC voltage of V phase
DCV W
DC voltage of W phase
STAT.OUT
Status output
TRIG.OUT
Trigger output
TRIG.IN
Trigger input (pause)
TYPE
Step type
JUMP STEP Jump destination step
JUMP CNT
Number of jump repetitions
S.PHASE
Starting phase angle
E.PHASE
Ending phase angle
PHAS. CHG Phase change
OUT IMP.
Output impedance
U PHA.OFFS
U phase offset
RAMP
Signal change
UV PHASE
U-V phase difference
RAMP
Signal change
UW PHASE
U-W phase difference
RAMP
Signal change
U PHASE
Clears the U phase offset
Single-phase, three-wire output or Three-phase output (PCR-LE optional)
1.
Select the output method (PCR-LE2 only).
Press OPR MODE and then WIRING (F5). If you select single-phase, three-wire output, the output
is generated from the OUTPUT 1P2W terminal block. If you select three-phase output, the output
is generated from the OUTPUT 3P4W (1P3W) terminal block.
2.
Set the Output Mode.
Press OPR MODE and then ACDC (F2) to select the output mode.
3.
Set the output voltage range.
Press RANGE(SHIFT+8) to select the output voltage range. You cannot set the range if the output
is turned on.
4.
Set the output voltage.
In AC+DC mode, the function key names are different. See “List of function keys.”
Single-phase, three-wire output
Set the AC voltage with phase voltages
To set all the phases at the same time, press V
and then PHAS VOLT (F1).
To set each phase separately, press U
VOLT (F1) or V VOLT (F2). To set the phase
difference, press UV PHASE (F4).
Set the DC voltage with phase voltages
Press V and then PHAS VOLT (F1). Then,
specify one-half the voltage that is required
for the line voltage. The V phase is set to
the same amplitude as the U phase but with
opposite polarity.
Set the output voltage with a line voltage
Press V and then LINE VOLT (F2). Then, set
the voltage. Use phase voltages to set the DC
voltage of AC+DC mode.
Three-phase output
Set the AC voltage with phase voltages
To set all the phases at the same time, press V
and then PHAS VOLT (F1).
To set each phase separately, press U VOLT (F1),
V VOLT (F2), or W VOLT(F3).
To set the phase difference, press UV PHASE (F4)
or UW PHASE (F5).
Set the AC voltage with line voltages
Press V and then LINE VOLT(F2).
Set the DC voltage (AC+DC mode only)
To set all the phases at the same time, press V
and then DC PH VOLT(F3).
To set each phase separately, press U
DCVOLT(F1), V DCVOLT(F2), or W DCVOLT(F2).
5.
Set the frequency. (AC/ AC+DC mode only)
Press F and then FREQ(F1).
6.
Turn the OUTPUT on.
Press the OUTPUT key.