124
PBZ
Program Examples
This section contains the following four program examples.
•
Example 1: A DC signal
•
Example 2: Superimposing an AC signal on a DC signal
•
Example 3: Changing a DC signal using a trigger signal input
•
Example 4: Generating an AC signal using a trigger signal input
,
For information on editing programs, see “Editing Programs and Steps”. For information on
executing programs, see “Executing Programs”.
Example 1: A DC Signal
Program overview
In CV mode, this program changes the voltage of a DC signal over time. The program takes
0.2 seconds to change between voltages. The DC signal starts at 0 V, rises to 12.0 V (stays at
this level for 1 second), rises to 14.0 V (stays at this level for 2 seconds), falls to 10.0 V (stays
at this level for 3 seconds), and falls to 0 V (stays at this level for 0.6 seconds). The program
will repeat this series of voltage changes until the process has been carried out 10 times.
See
3
2
1
4
5
7
6
8
9
Repeat
12.0
10.0
14.0
Output voltage (V)
0
Step number
Time for each step
Execution time
1 s
0.1 ms
2 s
3 s
0.2 s
1
0.2 s
0.6 s
0.2 s
0.2 s