106
PBZ
Step Settings
Step settings are displayed on the screen. Specify each setting within its input range.
Step Settings
The step editing screen is separated across five pages. AC signals use the internal signal
source.
•
DC signal and triggers (page 1/5)
•
AC signal amplitude and frequency (page 2/5)
•
DC signal ramp (slope) transitions (page 3/5)
•
AC signal and amplitude sweep (page 4/5)
•
AC signal and frequency sweep (page 5/5)
DC signal and triggers (page 1/5)
*1
The DC signal ramp and AC signal amplitude sweep both stop after 1000 seconds. The AC
signal frequency sweep repeats once every 1000 seconds. If you want to perform these
functions for lengths of time exceeding 1000 seconds, you have to combine multiple steps.
Item
Input range
Description
Factory default
setting
STEP
1 to 1024
The step number/the total number of steps in
the program. You can use a total of 1024 steps
in PRG.01 to PRG.16.
–
TIME
0:00:00.0001
0.1 ms to 1000 h
*1
The step execution time.
Hours : minutes : seconds; the resolution is 0.1
ms.
1.0000 s
DC
The same as the DC
signal’s input range
The DC signal setting. The input ranges for
some settings differ between bipolar and
unipolar modes.
2.000 V
OUTPUT
ON or OFF
ON: The output is turned on.
OFF: The output is turned off.
ON
TRIG
OUT
ON or OFF
ON: A trigger signal is generated when step
execution time begins.
OFF: Trigger signals are not generated.
OFF
TRIG IN
ON or OFF
ON: The PBZ enters the trigger signal input
standby state when step execution time begins.
OFF: Trigger signals are not detected.
OFF