PAS SERIES
Specifications 8-15
700W Type (cont.)
PAS
160-4
PAS
320-2
PAS
500-1.2
—
—
Output Specifications
Power
Rated output power
640 W
640 W
600 W
—
—
Voltage
Rated output voltage
160.0 V
320.0 V
500.0 V
—
—
Maximum preset voltage
(typ) *1
105 % of rating
—
—
0.1 % of 10 mV
—
—
Power supply fluctuation
0.05 % of 3 mV
—
—
0.05 % of 5 mV
—
—
Transient response
2 ms
—
—
Ripple
noise
80 mV
120 mV
170 mV
—
—
(RMS)
15 mV
20 mV
30 mV
—
—
Rise time (max)
250 ms (rated load)/ 150 ms (no load)
Fall time (max)
400 ms (rated load)/ 3 000 ms (no load)
Temperature coefficient
100 ppm/ °C (during analog remote control)
*1.
The maximum preset voltage and maximum preset current are provided for establishing a
constant voltage operation when the operation point is at [rated output voltage and rated
output current]. It does not guarantee power supply to the load exceeding the rated output
voltage.
To establish a constant voltage operation at the operation point [rated output voltage and
rated output current], set the output current (I Set) so that rated output current < I Set
≤
maximum preset current.
Likewise, to establish constant current operation, set the output voltage (V Set) so that
rate output voltage < V Set
≤
maximum preset voltage.
*2.
The difference between the actual output voltage and the preset value under constant volt-
age operation.
*3.
** % of rating denotes ** % of the rated output voltage.
*4.
Output voltage fluctuation with respect to ± 10 % fluctuation of the nominal input voltage
(ex. 100 VAC) under constant voltage operation.
*5.
Output voltage fluctuation when the output voltage is set to the rated output voltage and the
load is changed from rated load to no load (open load) under constant voltage operation.
*6.
The time it takes for the output voltage fluctuation to recover from outside 0.1 % + 10 mV
of the output voltage setting to within 0.1 % + 10 mV when the output current is changed
from 100 % to 50 % or 50 % to 100 % of the rating under constant voltage operation. The
output voltage at 100 % output current is used as a reference.
*7.
At a measurement frequency bandwidth of 10 Hz to 20 MHz.
*8.
At a measurement frequency bandwidth of 5 Hz to 1 MHz.
*9.
The time it takes for the output voltage to rise from 10 % to 90 % of the rating when the
OUTPUT is turned on.
*10.
The time it takes for the output voltage to fall from 90 % to 10 % of the rating when the
OUTPUT is turned off. The time it takes for the output voltage to fall to 60 V or less is
within 10 s when the POWER switch is turned off under OUTPUT on and no load condi-
tion.
*11.
At an ambient temperature range of 0 °C to 50 °C.
Summary of Contents for PAS 10-105
Page 10: ...VIII PAS SERIES This page has been intentionally left blank ...
Page 54: ...3 22 Basic Operation PAS SERIES This page has been intentionally left blank ...
Page 78: ...4 24 Remote Control PAS SERIES This page has been intentionally left blank ...
Page 131: ...PAS SERIES Specifications 8 13 This page has been intentionally left blank ...
Page 137: ...PAS SERIES Specifications 8 19 This page has been intentionally left blank ...
Page 145: ......