PAN-A
P-3
Pref
ace
• To protect a load from unexpectedly excessive voltage, the unit
includes a built-in OVP (over-voltage protection) circuit capable of
handling voltages 10 % - 110 % of the rated output voltage.
The OVP (over-voltage protection) circuit has a preset feature,
allowing you to check the OVP set voltage even when the unit is
being used.
With the above-mentioned features, PAN-A series units offers a wide
range of applications to laboratory experimental equipment, test
equipment for mass-production lines, power supply for aging, etc.
• Since this unit uses a phase control circuit for the pre-regula-
tor, output is superimposed with pulsive noise. Although the
noise level is kept a few tens of mV, it may still cause some
problem with certain types of applications. Please study this
issue carefully before choosing which unit to use.
Option
The following optional accessories are available for rack mounting.
• Rack mount frame RMF4M (Metric rack conforming to JIS standards)
RMF4 (Inch rack conforming to EIA standards)
• Blank panel
BP2, BP4
• Bracket
B22, B42, BH4M, BH4
•
The unit is furnished with air intake ports for forced air
cooling. For rack mounts, therefore, we request that
you mount a blank panel of at least one panel wide
*1
on the rack.
For details on optional accessories, contact your Kikusui agent.
*1. One panel wide; JIS standard: 50 mm, EIA standard: 44.45
mm
NOTE
CAUTION
Summary of Contents for PAN 110-1.5A
Page 4: ...II PAN A...
Page 44: ...2 12 PAN A...
Page 106: ...4 46 PAN A...
Page 156: ...7 26 PAN A...