Fig.4-26
Connection for master-slave-control series
operation using sensing (When the PAN-A
and PAN series are used together)
SENS
ON
OFF
S
S
1
2
7
8
13
14
19
4
3
2
1
12
11
10
9
8
7
6
5
CONTROL
Slave unit 1
Rear CONTROL
terminal board
4
3
2
1
12
11
10
9
8
7
6
5
CONTROL
Slave unit 2
Rear CONTROL
terminal board
Master unit
Rear OUTPUT
terminal board
Master unit
Front panel auxiliary
output terminals
Slave unit 1
Front panel auxiliary
output terminals
Slave unit 2
Front panel auxiliary
output terminals
Slave unit 1
Rear OUTPUT
terminal board
Slave unit 2
Rear OUTPUT
terminal board
S
S
S
S
+
-
10A
+
-
10A
+
-
10A
Master unit
Rear CONTROL
terminal board
Connect any one of the + and - terminals
to the chassis ground terminal, using a shorting bar.
Load
Remove
the shorting bar
of the end slave unit.
[2]
[2]
Rext
Rext ≈ (Ertg -10) * 1000 [Ω]
Ertg: rated output voltage of master unit
[1]
SW ON
Select the shortest and heaviest
gauge wires practical for this wiring