KIKUSUI ELECTRONICS CORP.
1-1-3 Higashiyamata, Tsuzuki-ku, Yokohama,
224-0023, Japan
www.kikusui.co.jp/en
■
OP03-KRC
Put the base hold angles to the both sides (right and left sides or front and rear
sides) of the base of rack.
The base hold angle has a long hole for M16 on the bottom side. Fix the rack with
anchor bolts.
■
OP04-KRC
Remove the hole caps on the top side, put the eyebolts to the rack.
No.
Description
Quantity
1
L-shape anchor
4
2
Bolt M10x35
8
3
Spring washer M10
8
4
Washer M10
8
5
Nut M10
8
Model
Fixing the right
and left sides
Fixing the front
and rear sides
W1
D1
W2
D2
KRC363L
670
450
270
1050
KRC273L
450
1050
KRC363
380
900
KRC273
380
900
KRC1603L
450
1050
KRC1203L
450
1050
KRC1603
380
900
KRC1203
380
900
Unit: mm
W1
D1
W2
D2
Location of anchor bolt holes
Base of
the rack
Base of
the rack
2
3
4
1
5
Hole
for
M16
Secure the rack with anchor bolts.
No.
Description
Quantity
1
Eyebolt
M12x22
4
2
Washer M12
4
1
2